Model 8507c piezoresistive pressure transducer, 8507c - xx - yyy – Atec Endevco-8507C Series User Manual

Page 3

background image

Calibration data

Data supplied for all parameters in certified performance section. optional calibrations
available for all parameters in typical performance section.

Model number definition

Data supplied for all parameters in certified performance section. optional calibrations
available for all parameters in typical performance section.

APPLIES TO CALIFORNIA FACILITY

Model 8507C

Piezoresistive pressure transducer

Continued product improvement necessitates that Meggitt (San Juan Capistrano), Inc reserve the right to modify these specifications without notice. Meggitt (San Juan

Capistrano), Inc maintains a program of constant surveillance over all products to ensure a high level of reliability. This program includes attention to reliability factors

during product design, the support of stringent Quality Control requirements, and compulsory corrective action procedures. These measures, together with conservative

specifications have made the name Endevco synonymous with reliability.

©Meggitt (San Juan Capistrano), Inc 30700 Rancho Viejo Road, San Juan Capistrano, CA 92675 USA

(800) 982-6732 • (949) 493-8181 fax (949) 661-7231 • www.endevco.com • Email: [email protected]

031611

Optional accessories

22409

4 conductor shielded cable

126

3 channel bridge amplifier

136

3 channel DC amplifier

436

Rack mount signal conditioner

4430A

Programmable bridge signal conditioner

4990A

OASIS rack system

Notes

1. Pressure ranges can be considered bidirectional, e.g., an 8507C-5 can be used to

measure +or - 5 psig. Sensitivity on the positive direction is typically within 1% of

sensitivity in the negative direction. Sensitivity calibration provided with each unit is for

the positive direction.

2. 1 psi = 6.895 kPa = 0.069 bar.
3. FSO (Full Scale Output) is defined as transducer output from 0 to + full scale pressure.
4. Zero Measurand Output (ZMO) is the transducer output with 0 psig applied.
5. Significantly higher thermal transient errors occur if the excitation voltage exceeds

10 Vdc. For sensitive phase change studies, many users reduce the excitation to 5 Vdc

or even 1 Vdc.

6. Equiv. PSI Per ISA-37.10, Para. 6.7, Proc. 1. The metal screen partially shields the

silicon diaphragm from incident radiation. Accordingly, light incident at acute angles to

the screen generally increases the error by a factor of 2 or 3.

7. Warm-up time is defined as elapsed time from excitation voltage “turn on” until the

transducer output is within ±1% of reading accuracy.

8. Use of excitation voltages other than 10.0 Vdc requires manufacture and calibration at

that voltage since thermal errors increase with high excitation voltages.

9. Units can be compensated over any 200°F (93°C) span from -65°F to +225°F

(-54°C to +107°C) on special order.

10. Maintain high levels of precision and accuracy using Endevco’s factory calibration

services. Call Endevco’s inside sales force at 800-982-6732 for recommended

intervals, pricing and turnaround time for these services as well as for quotations on

our standard products.

11. To extend vent tube, use Tygon® micro bore tubing, “.020 I.D X .060 O.D.”, -31ºC (-25ºF)

to +85ºC (185ºF), which is available from Cole-Parmer. For broader temperature range,

use silicone tubing.

Note: Tighter specifications are available on special order.

8507C - XX - YYY

Cable length is in inches (i.e. 8507C-15-120

has a length of 120 inches) if no dash is

specified the default length is 30 inches

Denotes range in PSIG

-1

-2

-5

-15

Basic model number