Optical measuring instruments – Atec Anritsu-ML9001A User Manual
Page 2

OPTICAL MEASURING INSTRUMENTS
48
EMC*
11
EMC*
11
Model
MA9411A/A1
MA9412A
MA9413A
MA9611A
Optical power
measurement
range
Measurement
accuracy
Resolution
Power
Operating temperature
Continuous light
–70 to +10 dBm*
4
(0.1 nW to 10 mW)
–70 to +7 dBm*
6
(0.1 nW to 5 mW)
±5%*
8
(0.5 to 0.95 µm)
±0.15 dB*
10
(±0.45 dB for –70 to –60
dBm)
W, W
(REL)
display: 0.1 to 1%, dBm display: 0.01 dB, dB
(REL)
display: 0.001 dB
100/115/120/200/220 Vac
+10
–15
%, 240 Vac
+4
–15
%, 50/60/400 Hz,
≤
40 VA
0° to 50°C
EN55011: 1991, Group 1, Class A
EN50082-1: 1992
±0.15 dB*
10
(±0.45 dB for –90 to –80
dBm)
±0.15 dB*
10
(±0.45 dB for –80 to –70
dBm)
±0.15 dB*
10
(±0.45 dB for –70 to –60
dBm)
–90 to 0 dBm*
4
(1 pW to 1 mW)
–90 to –3 dBm*
6
(1 pW to 0.5 mW)
–80 to +10 dBm*
4
(10 pW to 10 mW)
–90 to +7 dBm*
6
(1 pW to 5 mW)
±4.5%*
8
(0.85 µm)
±5%(0.5 to 0.95 µm)
–70 to +3 dBm*
5
(0.1 nW to 2 mW)
–80 to 0 dBm*
7
(10 pW to 1 mW)
±5%*
9
(1.0 to 1.6 µm)
Modulated light
Absolute accuracy
(–23 dBm)
Linearity continuous
light: 23°C, –23
dBm as reference
Model
MA9411A/A1
0.38 to 1.15 µm
Si photodiode
Direct to photodiode
40 (W) x 32 (H) x 62/73 (D)
mm,
≤
400 g
61 (W) x 42 (H) x 110 (D)
mm,
≤
800 g
42 (W) x 47 (H) x 160 (D)
mm,
≤
700 g
40 (W) x 32 (H) x 65 (D)
mm,
≤
400 g
9.5 mm
–
5 mm
–
Connector*
2
Direct to photodiode
Connector*
2
0.45 to 1.05 µm
Cooled-Si photodiode
0.75 to 1.7 µm
InGaAs photodiode
MA9412A
MA9413A
MA9611A
Wavelength range
Element
Active area diameter
Input type
Dimensions and mass
Sensor
Overall
Model
MA9612A
0.75 to 1.7 µm
0.75 to 1.8 µm
InGaAs photodiode
Ge photodiode
Connector*
2
61 (W) x 42 (H) x 110 (D)
mm,
≤
800 g
40 (W) x 32 (H) x 62/73 (D)
mm,
≤
400 g
42 (W) x 47 (H) x 110 (D)
mm,
≤
500 g
47 (W) x 61 (H) x 128 (D)
mm,
≤
800 g
–
5 mm
Direct to photodiode
Connector*
3
Cooled-Ge photodiode
MA9711A/A1
MA9712A
MA9714B
Wavelength range
Element
Active area diameter
Input type
Dimensions and mass
Model
MA9612A
MA9711A/A1
MA9712A
MA9714B
Optical power
measurement
range
Measurement
accuracy
Resolution
Power
Operating temperature
Continuous light
–100 to +3 dBm*
5
(0.1 pW to 2 mW)
–90 to 0 dBm*
7
(1 pW to 1 mW)
±5%*
9
(1.0 to 1.6 µm)
±5%*
9
(0.95 to 1.5 µm)
±0.15 dB*
10
(±0.45 dB for –90 to –80
dBm)
W, W
(REL)
display: 0.1 to 1%, dBm display: 0.01 dB, dB
(REL)
display: 0.001 dB
100/115/120/200/220 Vac
+10
–15
%, 240 Vac
+4
–15
%, 50/60/400 Hz,
≤
40 VA
0° to 50°C
EN55011: 1991, Group 1, Class A
EN50082-1: 1992
±0.15 dB*
10
(±0.45 dB for –40 to –30
dBm)
±0.15 dB*
10
(±0.45 dB for –60 to –50
dBm)
±0.15 dB*
16
(–37 to +20
dBm, ±0.45 dBm for –47 to
–37 dBm)
–40 to +10 dBm*
5
(0.1 µW to 10 mW)
–60 to +7 dBm*
7
(1 nW to 5 mW)
–60 to +10 dBm*
5
(1 nW to 10 mW)
–70 to +7 dBm*
7
(0.1 nW to 5 mW)
±4.5% (1.3 µm)
±5%(0.95 to 1.6 µm)
–47 to +23 dBm*
12
(20 nW to 200 mW)
–57 to +20 dBm*
13
(2 nW to 100 mW)
±4.5% (1.55 µm)*
14
±5%(0.95 to 1.6 µm)*
15
Modulated light
Absolute accuracy
(–23 dBm)
Linearity continuous
light: 23°C, –23
dBm as reference
*
1: Twelve modulation frequencies including 270 Hz and 1 kHz
*
2: FC-type connector standard
*
3: Only for PC type SM fiber (10/125 µm, NA 0.1)
*
4: At 0.85 µm
*
5: At 1.3 µm
*
6: At 0.85 µm, 270 Hz
*
7: At 1.3 µm, 270 Hz
*
8: For wavelengths other than 0.85 µm, specified at 23° ±5°C
*
9: For wavelengths other than 1.3 µm, specified at 23° ±5°C
*
10: At 23° ±5°C
*
11: Electromagnetic compatibility
*
12: At 1.55 µm
*
13: At 1.55 µm, 270 Hz
*
14: At 1.55 µm, 0 dBm
*
15: At 0 dBm
*
16: Reference = 0 dBm
Note: When an optical fiber is used, performance is guaranteed for a fiber core diameter of up to 62.5 m and an NA of up to 0.29.
When any other fiber is used, a measurement error may occur.
Safety
EN61010-1: 1993 (Installation Category
ΙΙ
, Pollution Degree
ΙΙ
)
Safety
EN61010-1: 1993 (Installation Category
ΙΙ
, Pollution Degree
ΙΙ
)