beautypg.com

Optical measuring instruments – Atec Anritsu-ML9001A User Manual

Page 2

background image

OPTICAL MEASURING INSTRUMENTS

48

EMC*

11

EMC*

11

Model

MA9411A/A1

MA9412A

MA9413A

MA9611A

Optical power
measurement
range

Measurement
accuracy

Resolution

Power

Operating temperature

Continuous light

–70 to +10 dBm*

4

(0.1 nW to 10 mW)

–70 to +7 dBm*

6

(0.1 nW to 5 mW)

±5%*

8

(0.5 to 0.95 µm)

±0.15 dB*

10

(±0.45 dB for –70 to –60
dBm)

W, W

(REL)

display: 0.1 to 1%, dBm display: 0.01 dB, dB

(REL)

display: 0.001 dB

100/115/120/200/220 Vac

+10

–15

%, 240 Vac

+4

–15

%, 50/60/400 Hz,

40 VA

0° to 50°C

EN55011: 1991, Group 1, Class A
EN50082-1: 1992

±0.15 dB*

10

(±0.45 dB for –90 to –80
dBm)

±0.15 dB*

10

(±0.45 dB for –80 to –70
dBm)

±0.15 dB*

10

(±0.45 dB for –70 to –60
dBm)

–90 to 0 dBm*

4

(1 pW to 1 mW)

–90 to –3 dBm*

6

(1 pW to 0.5 mW)

–80 to +10 dBm*

4

(10 pW to 10 mW)

–90 to +7 dBm*

6

(1 pW to 5 mW)

±4.5%*

8

(0.85 µm)

±5%(0.5 to 0.95 µm)

–70 to +3 dBm*

5

(0.1 nW to 2 mW)

–80 to 0 dBm*

7

(10 pW to 1 mW)

±5%*

9

(1.0 to 1.6 µm)

Modulated light

Absolute accuracy
(–23 dBm)

Linearity continuous
light: 23°C, –23
dBm as reference

Model

MA9411A/A1

0.38 to 1.15 µm

Si photodiode

Direct to photodiode

40 (W) x 32 (H) x 62/73 (D)
mm,

400 g

61 (W) x 42 (H) x 110 (D)
mm,

800 g

42 (W) x 47 (H) x 160 (D)
mm,

700 g

40 (W) x 32 (H) x 65 (D)
mm,

400 g

9.5 mm

5 mm

Connector*

2

Direct to photodiode

Connector*

2

0.45 to 1.05 µm

Cooled-Si photodiode

0.75 to 1.7 µm

InGaAs photodiode

MA9412A

MA9413A

MA9611A

Wavelength range

Element

Active area diameter

Input type

Dimensions and mass

Sensor

Overall

Model

MA9612A

0.75 to 1.7 µm

0.75 to 1.8 µm

InGaAs photodiode

Ge photodiode

Connector*

2

61 (W) x 42 (H) x 110 (D)
mm,

800 g

40 (W) x 32 (H) x 62/73 (D)
mm,

400 g

42 (W) x 47 (H) x 110 (D)
mm,

500 g

47 (W) x 61 (H) x 128 (D)
mm,

800 g

5 mm

Direct to photodiode

Connector*

3

Cooled-Ge photodiode

MA9711A/A1

MA9712A

MA9714B

Wavelength range

Element

Active area diameter

Input type

Dimensions and mass

Model

MA9612A

MA9711A/A1

MA9712A

MA9714B

Optical power
measurement
range

Measurement
accuracy

Resolution

Power

Operating temperature

Continuous light

–100 to +3 dBm*

5

(0.1 pW to 2 mW)

–90 to 0 dBm*

7

(1 pW to 1 mW)

±5%*

9

(1.0 to 1.6 µm)

±5%*

9

(0.95 to 1.5 µm)

±0.15 dB*

10

(±0.45 dB for –90 to –80
dBm)

W, W

(REL)

display: 0.1 to 1%, dBm display: 0.01 dB, dB

(REL)

display: 0.001 dB

100/115/120/200/220 Vac

+10

–15

%, 240 Vac

+4

–15

%, 50/60/400 Hz,

40 VA

0° to 50°C

EN55011: 1991, Group 1, Class A
EN50082-1: 1992

±0.15 dB*

10

(±0.45 dB for –40 to –30
dBm)

±0.15 dB*

10

(±0.45 dB for –60 to –50
dBm)

±0.15 dB*

16

(–37 to +20

dBm, ±0.45 dBm for –47 to
–37 dBm)

–40 to +10 dBm*

5

(0.1 µW to 10 mW)

–60 to +7 dBm*

7

(1 nW to 5 mW)

–60 to +10 dBm*

5

(1 nW to 10 mW)

–70 to +7 dBm*

7

(0.1 nW to 5 mW)

±4.5% (1.3 µm)
±5%(0.95 to 1.6 µm)

–47 to +23 dBm*

12

(20 nW to 200 mW)

–57 to +20 dBm*

13

(2 nW to 100 mW)

±4.5% (1.55 µm)*

14

±5%(0.95 to 1.6 µm)*

15

Modulated light

Absolute accuracy
(–23 dBm)

Linearity continuous
light: 23°C, –23
dBm as reference

*

1: Twelve modulation frequencies including 270 Hz and 1 kHz

*

2: FC-type connector standard

*

3: Only for PC type SM fiber (10/125 µm, NA 0.1)

*

4: At 0.85 µm

*

5: At 1.3 µm

*

6: At 0.85 µm, 270 Hz

*

7: At 1.3 µm, 270 Hz

*

8: For wavelengths other than 0.85 µm, specified at 23° ±5°C

*

9: For wavelengths other than 1.3 µm, specified at 23° ±5°C

*

10: At 23° ±5°C

*

11: Electromagnetic compatibility

*

12: At 1.55 µm

*

13: At 1.55 µm, 270 Hz

*

14: At 1.55 µm, 0 dBm

*

15: At 0 dBm

*

16: Reference = 0 dBm

Note: When an optical fiber is used, performance is guaranteed for a fiber core diameter of up to 62.5 m and an NA of up to 0.29.

When any other fiber is used, a measurement error may occur.

Safety

EN61010-1: 1993 (Installation Category

ΙΙ

, Pollution Degree

ΙΙ

)

Safety

EN61010-1: 1993 (Installation Category

ΙΙ

, Pollution Degree

ΙΙ

)