Atec Anritsu-S331L User Manual
Page 2

2
PN: 11410-00616 Rev. B
S331L TDS
Specifications
Site Master™ S331L
Cable and Antenna Analyzer
All specifications and characteristics apply to revision 1 instruments under the following conditions, unless otherwise stated: 1) Instrument within its recommended calibration cycle, 2) After
5 minutes of warm-up time, where the instrument has completely stabilized to the ambient temperature, 3) Internal frequency reference used, 4) Cable analyzer and VNA measurements applicable
after standard OSL calibration is performed using Anritsu calibration components, 5) Typical data does not include guard band for measurement uncertainty and temperature variation and is not
warranted, 6) All specifications subject to change without notice, 7) Recommended calibration cycle is 12 months.
Measurements
Measurements
VSWR
Return Loss
Cable Loss (One Port)
Distance-to-Fault (DTF) Return Loss
Distance-to-Fault (DTF) VSWR
Setup Parameters–Classic Mode
Measurement Display
Single Display with independent markers
Frequency
F1/F2
DTF
D1/D2, DTF Aid, Cable Loss, Propagation Velocity, Cable type
Windowing
Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude
Top, Bottom Auto Scale, Full Scale
Sweep
Data Points, Run/Hold, Single/Continuous, RF Immunity (High/Low)
Data Points
130, 259, 517, 1033
Markers
Markers 1 to 6 (On/Off), Delta Markers 2 to 4 (Ref M1), Marker to Peak/Valley, Marker Table, Marker 5
(Peak/Valley between M1 & M2), Marker 6 (Peak/Valley between M3 & M4)
Traces
Copy Trace To Memory, Trace Display, Trace Math
Limit Line
On/Off, Edit Value, Limit Alarm, Pass/Fail On/Off, Limit Preset
Calibration
Cal Type OSL/Standard/FlexCal
™
/InstaCal
™
Save/Recall
Setups, Measurements, Screen Shots
Setup Parameters–Advanced Mode
Measurement Display
Single Display with independent markers
Frequency
Start Frequency (F1), Stop Frequency (F2)
DTF
Start Distance (D1), Stop Distance (D2), Units m/ft, DTF Aid, Cable List, Cable Loss, Propagation Velocity
Windowing
Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude
Top, Bottom, Auto Scale, Full Scale
Sweep
Data Points, Run/Hold, Single/Continuous, RF Immunity (High/Low)
Data Points
130, 259, 517, 1033
Markers
Markers 1 to 8 (On/Off), Delta Markers 2 to 8 (Ref M1), Marker to Peak/Valley, Marker Table, Marker 5 & 7
(Peak/Valley between M1 & M2), Marker 6 & 8 (Peak/Valley between M3 & M4)
Traces
Copy Trace to Memory, Trace Display, Trace Math
Limit Line
On/Off, Edit Value, Limit Alarm, Pass/Fail On/Off, Limit Preset
Calibration
Cal Type OSL/Standard/FlexCal
™
/InstaCal
™
Save/Recall
Setups, Measurements, Screen Shots
Frequency
Frequency Range
2 MHz to 4 GHz
Frequency Accuracy
± 5 ppm @ 23 °C ± 3 °C
Frequency Resolution
1 kHz
Power
Output Power
+3 dBm, typical
Interference Immunity
On-Channel
+17 dBm outside calibrated sweep range
On-Frequency
+13 dBm within calibrated sweep range
Measurement Speed
Return Loss
≤ 1.50 ms/data point, RF immunity low, typical
Distance-to-Fault
≤ 1.75 ms/data point, RF immunity low, typical