beautypg.com

Enter enter – Associated Equipment 12-1012 Quick Guide User Manual

Page 6

background image

6

29. During cranking when it detects that there is

no drop in voltage, it will display the following
screen:












30. To exit the program, pressing the

key at any

moment will exit and return back to the main menu
screen.

Alternator Test

No load testing at 3000 RPM:

31. With engine OFF, place the vehicle

transmission in NEUTRAL for Manual and
PARK for Automatic and apply the parking
brake.

32. Pressing key once will scroll down to the

“Alternator Test”









33. Press

key to continue and the display

will show:







34. Starts the engine then press key again and

the screen will prompt you as shown below:










35.

After that press

key again and it

show as below:










36. Press

key will show the results of the

test:










37. If either minimum or maximum charging volts

are not within the voltage range limits then it
will display one of the screen as below (Fig. 1
& Fig. 2) and it will prompt you to check the
alternator system for the fault.










Fig. 1

Not detected...

Check connection

and test again

Cranking Test

Start Engine and

keep it running


Then press

Rev engine up to

3,000 rpm,

Continue this rpm

for 10 sec.

3000 RPM

Max 14.07 <15.0 V

Min 13.5 >13.3 V

Enter to proceed

13.96 V

ChargeVolts:13.96V

Result: Good

Enter to proceed

NO LOAD TEST

Min Charge:12.96V

Result: LOW

Check Alt System

NO LOAD TEST

Battery Test

Grounding Test

Starter Test

Alternator Test

Enter

Enter