3.3 Changing Oil
Engine oil is HOT! Avoid contact with skin and clothing.
WARNING! BURN HAZARD
Switch the engine OFF before draining the oil.
CAUTION!
Recommended oil is synthetic SAE 10W-40 when ambient temperature is above 32° F (0° C).
Synthetic SAE 0W-40 is recommended if operating temperatures are below 32° F (0° C).
Engine oil capacity: 15.2 fl oz (.45L)
Tools Required:
#2 Philips Head Screwdriver
Oil Drain Pipe
Drain the oil while the engine is still warm to assure thorough draining.
NOTE:
Procedure:
1. Remove the maintenance cover.
2. Remove the oil dipstick (use the slots in the oil drain pipe to easily remove the dipstick).
3. Install the oil drain pipe (included with the generator).
4. Drain the dirty oil into a container. Be sure to allow time for the oil to drain completely.
5. Refill with the recommended oil, ensuring the oil level is at the upper line on the dipstick.
6. Reinstall the dipstick and the maintenance cover and tighten the screws securely.
Dispose of used motor oil according to local environmental disposal regulations. Do not throw it in the trash or pour it on
the ground.
ATTENTION:
L
L/2
Fig. 3-2, Changing Oil
Dip Stick
Oil Fill Hole
Minimum
Oil Level
Maximum
Oil Level
Oil Drain Pipe