Alpha Technologies IDH3 User Manual
Page 20
20
745-420-B0-001 Rev. A
4.0
Using the Ethernet (Craft) Port, continued
4.1
IDH3 Web Interface, continued
4.1.1 System Overview, continued
Confi guring the sysName and sysLocation OIDs
It is also possible to confi gure the sysName (1.3.6.1.2.1.1.5.0) and sysLocation
(1.3.6.1.2.1.1.6.0) OIDs from the web interface. This feature is password protected.
There are both Admin and User usernames and passwords. Both usernames (Admin
and User) have the authority to set sysName and sysLocation. The passwords can
be changed via the Broadcom httpMgmt MIB. The specifi c OIDs and default values
are shown below.
Table 5. OIDs for Usernames and Passwords for Web Interface Access
Parameter
OID
Default
httpAdminId 1.3.6.1.4.1.4413.2.2.2.1.1.3.1.0
edarglloT
httpAdminPassword
1.3.6.1.4.1.4413.2.2.2.1.1.3.2.0
aDm1n$TR8r
httpUserId
1.3.6.1.4.1.4413.2.2.2.1.1.3.3.0
Tollgrade
httpUserPassword
1.3.6.1.4.1.4413.2.2.2.1.1.3.4.0
Tollgrade
The IDH3 web pages do not automatically refresh, so the user must manually reload each one to view the
most current data.
NOTE:
Table 6. OIDs for Port Management
Parameter
OID
Default
httpCMMgmtPort 1.3.6.1.4.1.2082.5.5.1.1.1.0
80
httpCPEMgmtPort 1.3.6.1.4.1.2082.5.5.1.1.2.0
80
It is possible to change the port number for Web Access and to disable it entirely.
The table below lists the Parameters, OIDs, and default settings. Setting the Port
value to sero (0) will disable access to the HTTP server for the given interface. The
specifi c OIDs and their default values are listen in Table 6. The port must be open to
use all of the deatures described in the following sections.