Alpha Technologies Te41, 48V User Manual
Page 43

1
1
2
2
3
3
4
4
5
5
6
6
D
D
C
C
B
B
A
A
5
11
SCHEMATIC, 48V ENCLOSURE W/
747-654-05
P/A
Title
SIZE
DWG NO.
Rev
Sheet
of
C
22kAIC AC PANEL, FAN DOOR,
V3 DUAL COMPARTMENT
THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF
ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED
FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
TYPE
ISSUE
DATE
REVISION
LTR
DESCRIPTION
DATE
APPD
S5
K2
K4
K3
K6
K5
K7
K8
K0
2
1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
TB1
COM
N.C.
N.O.
N.C.
N.O.
COM
COM
N.C.
N.O.
COM
N.C.
N.O.
COM
N.C.
N.O.
N.C.
N.O.
COM
N.C.
N.O.
COM
N.C.
N.O.
COM
48
49
50
51
52
53
54
55
56
V1 -
V1 +
I1 -
I1 +
I2 -
I2 +
N.C.
COM
N.O.
47
46
45
44
43
42
41
40
TB5
TB4
+ POWER
- POWER
SYSTEM INPUTS
LVD #1 CONTROL (K1)
24
25
26
27
28
29
30
31
32
33
34
36
38
35
37
39
D4_2
D4_1
D3_2
D3_1
D2_2
D2_1
D1_2
D1_1
GP4 -
GP4 +
GP3 -
GP3 +
GP2 -
GP2 +
GP1 -
GP1 +
1
20
2
21
3
22
4
23
5
24
6
25
7
8
9
10
11
12
13
14
15
16
17
18
19
27
26
J2
1
20
2
21
3
22
4
23
5
24
6
25
7
8
9
10
11
12
13
14
15
16
17
18
19
27
26
P1
I/O EXTENSION BOARD ASSEMBLY
RELAY OUTPUTS
GENERAL
PURPOSE INPUTS
DIGITAL INPUTS
I/O EXTENSION WIRE HARNESS #1 - P/N 877-XXX-20
6
5
8
7
1
1
20
2
21
3
22
4
23
5
24
6
25
7
8
9
10
11
12
13
14
15
16
17
18
19
27
26
P9
1
20
2
21
3
22
4
23
5
24
6
25
7
8
9
10
11
12
13
14
15
16
17
18
19
27
26
J4
TO J9 ON CXCM4 BACKPLANE I/F BOARD
TO P4 ON CXCM4 BACKPLANE I/F BOARD
CABLE ASSEMBLY - P/N 877-630-20
CABLE ASS'Y - P/N 877-631-20
TB1
1
20
2
21
3
22
4
23
5
24
6
25
7
8
9
10
11
12
13
14
15
16
17
18
19
27
26
NOKIA BTS ALARM INTERFACE CABLE ASS'Y - P/N 870-289-10
'AC FAIL' ALARM (K7)
ORG - #22 AWG
YEL - #22 AWG
BRN - #22 AWG
BLU - #22 AWG
VIO - #22 AWG
GRY - #22 AWG
BRN - #22 AWG
ORG - #22 AWG
BLU - #22 AWG
VIO - #22 AWG
GRY - #22 AWG
YEL - #22 AWG
WHT/BLU
BLU/WHT
WHT/ORG
ORG/WHT
WHT/GRN
GRN/WHT
WHT/BRN
BRN/WHT
WHT/SLT
SLT/WHT
RED/BLU
BLU/RED
RED/ORG
ORG/RED
RED/GRN
GRN/RED
RED/BRN
BRN/RED
RED/SLT
SLT/RED
BLK/BLU
BLU/BLK
BLK/ORG
ORG/BLK
ON LOWER RECTIFIER SHELF
ON LOWER RECTIFIER SHELF
TB6
TB10
TB11
TB12
TB2
TB13
TB3
TB14
10
9
34
35
3
4
34
BLK - #18 AWG
(CUSTOMER CONNECTION)
35
BLK - #18 AWG
'LVD MANUAL OVERRIDE IN ALARM'
'DC DISTRIBUTION CB/FUSE FAIL ALARM'
SYSTEM INPUT/OUTPUT & ALARM INTERFACE SIGNAL WIRING:
BLK - #18 AWG
18
BLK - #18 AWG
37
BLK - #18 AWG
CABLE ASSEMBLY - P/N 877-XXX-20
N.C.
COM
RED - #18 AWG
BLK - #18 AWG
'DOOR INTRUSION' ALARM
(FROM SHEET 6)
'RECTIFIER MAJOR' ALARM
'BATTERY ON DISCHARGE' ALARM
67
68
* TIE BACK ALL UNUSED ALARM WIRE PAIRS
'RECTIFIER MINOR' ALARM
BLK/GRN
GRN/BLK
BLK/BRN
BRN/BLK
BLK/SLT
SLT/BLK
YEL/BLU
BLU/YEL
YEL/ORG
ORG/YEL
YEL/GRN
GRN/YEL
BLK - #18 AWG
1
2
3
4
18
9
5
10
6
7
8
FROM DC POWER BREAKER
(REFER TO SHEET 10)
39
40
43
44
45
46
2
57
39
54
40
'SYSTEM CONTROLLER FAIL' ALARM (K0)
I/O EXTENSION WIRE HARNESS #2 - P/N 877-XXX-20
J5
TO P5 ON CXCM4 BACKPLANE
P/N 707-440-20
(REFER TO SHEET 4)
INTERFACE BOARD ASSEMBLY
BLK - #18 AWG
BLK - #18 AWG
57
ALARM WIRING TERMINAL BLOCKS
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
P/N 707-449-20
49
49
BLK - #18 AWG
BLK - #18 AWG
BLK - #18 AWG
JUMPERS IN
4 PLACES
58
55
55
'LVD #2 CONTROL (K2)'
'LVD #3 CONTROL (K3)'
'LVD #4 CONTROL (K4)'
I4 +
I4 -
I3 +
I3 -
1
46
45
44
43
* NOTE: ALL ALARM OUTPUT RELAYS ARE
PROGRAMMED IN THE DEFAULT 'DE-ENERGIZED'
STATE.
N.O.
COM
FROM AIR CONDITIONER STATUS ALARM OUTPUT CABLE
(REFER TO SHEET 2)
59
60
YEL
RED
DIGITAL INPUT SETTINGS:
D3 = ACTIVE HIGH
D4 = ACTIVE HIGH
DISTRIBUTION CENTRE BANK #3 & 4
FROM DC POWER BREAKER
(REFER TO SHEET 9)
DIST. CENTRE BANK #1 & 2
OFF TO THE SIDE OF BLOCK.
'RECTIFIER MAJOR' ALARM (K6)
'BATTERY ON DISCHARGE' ALARM (K8)
'RECTIFIER MINOR' ALARM (K5)
YEL - #18 AWG
61
62
N.O.
COM
RED
BLK
RED
BLK
FROM FAN CONTROLLER PCB
(REFER TO SHEET 7)
AC FAIL
80
80
BLK - #18 AWG
TO FAN POWER RELAY COIL
(REFER TO SHEET 7)
82
TB2
TB3
TB4
TB5
TB6
TB7
TB8
TB9
TB10
TB11
TB12
TB13
TB14
TB15
TB16
TB17
TB18
TB19
TB20
TB21
TB22
TB23
TB24
TB25
TB26
TB27
TB28
TB29
TB30
TB31
TB32
TB33
TB34
TB35
TB36
TB37
TB38
TB39
TB40
N.O.
COM
N.O.
COM
ENCLOSURE HIGH TEMPERATURE
ALARM (FROM SHEET 6)
ENCLOSURE LOW TEMPERATURE
ALARM (FROM SHEET 6)
63
64
65
66
RED - #22 AWG
BLK - #22 AWG
RED - #22 AWG
BLK - #22 AWG
P/N 858-048-10
82
P/N 858-065-10
RED - #18 AWG
37