Maintenance
© Gardner Denver Deutschland GmbH
27 / 32
610.44440.40.000
Interval
Maintenance procedure
Drain off the decalcifying liquid from the unit (see chapter 8.1, "Draining down",
page 23).
Flushing the pump casing(see page 26).
Reconnect the piping / hoses.
Start up the unit again (see chapter 6, "Commissioning", page 19).
Dispose of the decalcifying agent in accordance with the applicable directives.
2.5 years or
20,000 operating
hours
Re-grease or renew roller bearings
Open roller bearings and adjacent grease cups are to be cleaned of old grease
and contamination.
Fill approx. 50% of the free space in the roller bearings and approx. 65% of the
volume in the adjacent areas with grease.
Grease type: UNIREX N3 (ESSO Co.)
Alternative grease acc. DIN 51825-K3N
Sealed roller bearings are to be renewed and the adjacent areas do not require
greasing.
It is recommended that the rotary seal, the V-ring and the valve head are
checked for wear and replaced if necessary.
The specified intervals apply only when using UNIREX N3 grease. Avoid mixing
different types of grease.
9.2
Repairs / Troubleshooting
Fault
Cause
Correction
Remedy
Electrical power sup-
ply failure
Check fuses, terminals and cables for continuity. Re-
pair any break in continuity.
Electrician
To free it, rotate the shaft:
2BV2 …:
Screw in an M8 bolt of suf-
ficient length into the shaft
end on the external fan
side.
Use a wrench to turn the
shaft manually.
Remove the bolt.
2BV5 …:
Remove the fan guard.
Turn the external fan
by hand.
Refit the fan guard.
Operator
See "Decalcifying the unit", page 26.
Operator
See "Flushing the pump casing", page 26.
Operator
Impeller does not ro-
tate freely
Check the clearance adjustment on the impeller and
readjust if necessary.
Service
Foreign matter in the
unit
Remove the foreign matter.
Check that the unit functions correctly.
Service
Defective impeller
Replace the impeller.
Service
Motor does
not start
Defective motor bear-
ing
Replace the motor bearing.
Service
Short-circuit in the
winding
Check
the
winding.
Electrician
Circuit
breaker trips
out again
after it has
been
switched on
Motor
overloaded
When operating with supply of the operating-liquid:
Check the operating-liquid flow-rate and if necessary
reduce it (see chapter 7.4, "Checking and correcting
the operating-liquid flow-rate", page 22).
Operator