Pump Specifications LOWPRO41LP
Hp
4/10
Volts
115
Phase
1
Full Load Amps
12
Hz
60
Solids-handling
2"
Discharge size
2"
NOTE: The LowPro has a shut-off head
(maximum lift) of 19 feet. Actual maximum
useable head to provide adequate flow is
approximately 17.5 feet and may be less
depending on amount of run and friction loss
factors. Please consult factory for proper
pump sizing.
Item Part No.
Description
Qty.
1
4622000
Tank, low profile
1
2
LE41LP
Pump, 4/10Hp sewage, 115V
1
3
4623000
Nipple, 2” PVC Sched. 80
1
4
462100B
Cover, pump access
1
5
4616000
Switch, vertical master
1
6
462000B
Cover, switch access
1
7
8131000
Washer, flat 1/4” X 3/4” S.S.
14
8
8129000
Bolt, 1/4”-20 X 5/8”, Hex head S.S.
14
9
4022000
Stopper, double cord hole
1
10
4624000
Closet Flange, brass
1
11
8018000
Screw, 1/4”-20 X 5/8” slotted Flt. Hd.
4
12
4039000
Gasket, cover 1” X 1/8” tape
1
13
4039RA0
Gasket Tape, for closet flange
1
14
CV200C
Check Valve, 2” PVC compression fit
1
15
4762000
Grommet, Pipe seal, 2”
1
16
4627000
Wax Ring
1
17
4626000
Closet flange extension kit
1
18
4625000
Closet bolt kit
1
4. Pump Specifications and Parts List
Refer to the diagram
to adjust the float
switch (5). The
pump should engage
at a waste depth of
approximately 4.0”
and pump down to
around 3.0”. To
adjust the float
switch, remove the
switch access cover
(6) and lift the float
switch (5) out of the
tank. After adjusting
to the lengths
pictured above,
replace the switch by
placing the cord
between the two
bosses. Reattach
the access cover to
the tank.
Fig. 6
Spacer (one each of 1/4" and 1/2" provided.
May be stacked for total of 3/4")
Finish Flooring (Tile, Linoleum etc.)
Sub-flooring (Plywood etc.)