QuickTree® settings for PRO370 and PRO380 Systems:

When servicing the QuickTree

®

place the switch cord into the trough or channel then slip the stainless steel rod through the clamp and

tighten the screw with a Philips screw driver do not over tighten. Flats have been formed on the rod to designate float positioning the

screw should be tightened onto the flat. The tether length is the amount of cord between the clamp and float.

TETHER LENGTH (SWITCH TO CLAMP)

ROD

POSITION Alarm Float Control Float Alarm Float Control Float

1

3.5"

2

3.5"

3

3.0"

4

3.5"

P370

P380

Float positions 1, 2, 3 and 4

are identified by a “flat”

stamped into the stainless

steel rod. 1 is highest, 4 is

lowest.

P370 and P380 systems have different tether

lengths. See above chart for proper tether length

and correct rod position.