Gorman-Rupp Pumps S3B65-E6 460/3 861279 thru 1217130 User Manual
Page 28
OM−04151
S SERIES PUMPS
PAGE C − 2
OPERATION
ceeds the temperature for which the pump was de-
signed, if the control box fails to provide overload
or thermal protection, or if the pump is operated
against a closed discharge valve for an extended
period of time.
Do not start the pump more than 6 times
per hour. If the motor does not cool be-
tween starts it will overheat, resulting in
damage to the motor windings.
As a safeguard against rupture or explosion due to
heat, models equipped with oil-lubricated motors
are fitted with a pressure relief valve which will open
if vapor pressure within the pump motor reaches a
critical point. Always terminate power to the pump
and control before investigating pump or control
box problems.
Approach the pump cautiously after it
has been running. Although the motor is
cooled by the liquid being pumped, nor-
mal operating temperatures can be high
enough to cause burns. The tempera-
ture will be especially high if operated
against a closed discharge valve. Never
operate against a closed discharge
valve for long periods of time.
If overheating does occur, stop the pump immedi-
ately and allow it to cool before servicing it. Ap-
proach any overheated pump cautiously.
Overheated pumps can cause severe
burns and injuries. If overheating of the
pump occurs:
1. Stop the pump immediately.
2. Ventilate the area.
3. Allow the pump to completely cool.
4. Check the temperature before ser-
vicing.
5. Vent the pump slowly and cau-
tiously
6. Refer to instructions in this manual
before restarting the pump.
Is so equipped, it is recommended that the pres-
sure relief valve assembly be replaced at each
overhaul, or any time the pump motor overheats
and activates the valve. Never replace this valve
with a substitute which has not been specified or
provided by the Gorman-Rupp Company.
Impeller Rotation
Check impeller rotation as follows before operation
to ensure that the impeller is rotating in the correct
direction.
While checking impeller rotation, secure
the pump to prevent the power cable from
coiling.
Suspend the pump from the lifting device fitted on
the pump. Apply power briefly and note the direc-
tion of pump kickback. As viewed from the top, the
pump should kick in a counterclockwise direc-
tion; this will indicate that impeller rotation is cor-
rect.
If the pump kicks in a clockwise direction, impeller
rotation is incorrect. If the pump is powered by a
three-phase motor, have a qualified electrician in-
terchange the control box connections of any two
pump motor power leads. Re-check pump kick-
back; it should now be in a counterclockwise direc-
tion.
If rotation is incorrect on a single-phase motor, con-
tact the factory before installing the pump.
- S3B65-E6 575/3 1199517 and up S3C1 230V 3P 861279 thru 1207589 S3C1 460V 3P 861279 thru 1207589 S3C18 230V 3P 861279 thru 1217140 S3C18 460V 3P 861279 thru 1217140 S4C65-E10 460/3 861279 thru 1142084 S4D65-E10 460/3 861279 thru 1141092 S2F1-E1 230/3 997771 thru 1225728 S2F1-E1 460/3 997771 thru 1225728