Operation - section c – Gorman-Rupp Pumps S3B65-E6 460/3 861279 thru 1217130 User Manual
Page 27
S SERIES PUMPS
OM−04151
PAGE C − 1
OPERATION
OPERATION − SECTION C
GENERAL INFORMATION
Review all SAFETY information in Section A.
This pump is designed to handle most
non-volatile, non-flammable liquids. Do
not attempt to pump any liquids for
which your pump is not approved, or
which may damage the pump or endan-
ger personnel as a result of pump fail-
ure. Consult the factory for specific ap-
plication data.
Follow the instructions on all tags, labels and de-
cals attached to the pump.
Pump Performance
Since operation of the pump motor is de-
pendent upon the quality and performance
of the electrical controls, the pump warran-
ty is valid only when controls have been
specified or provided by The Gorman-
Rupp Company.
Refer to the pump Specification Data Sheet or the
accompanying Parts List Manual for the specific
performance for your pump.
Control Box
A control box is provided to facilitate operation of
the pump. It contains controls for starting and stop-
ping the pump, and provides overload protection
for the pump motor. The pump control (for models
10 horsepower and up) may be equipped with an
optional automatic liquid level sensing device, in
which case those circuits are also contained within
the control box. Pump models under 6 horsepower
require an additional control box to incorporate liq-
uid level controls.
The pump motor and control box are not
designed to be explosion-proof. Do not
operate in an explosive atmosphere.
Any control box used to operate the
pump must be approved by the Gor-
man-Rupp Company for the application.
Improper location of a non-explosion
proof control box could result in de-
struction of equipment, injury or death
to personnel.
See the operating instructions furnished with the
control box, and with other optional accessories
and controls, before attempting to start the pump.
PUMP OPERATION
Liquid Temperature and Overheating.
Overheated pumps can cause severe
burns and injury. If the pump becomes
overheated:
1. Stop the pump immediately.
2. Lock out the power to the control
panel to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Close the discharge valve (if
used).
5. Refer to instructions in this manual
before restarting the pump.
Overheating can occur if the pump is misapplied;
if it is started more than 6 times within one hour; if
the temperature of the liquid being pumped ex-
- S3B65-E6 575/3 1199517 and up S3C1 230V 3P 861279 thru 1207589 S3C1 460V 3P 861279 thru 1207589 S3C18 230V 3P 861279 thru 1217140 S3C18 460V 3P 861279 thru 1217140 S4C65-E10 460/3 861279 thru 1142084 S4D65-E10 460/3 861279 thru 1141092 S2F1-E1 230/3 997771 thru 1225728 S2F1-E1 460/3 997771 thru 1225728