beautypg.com

Gorman-Rupp Pumps 06C1-GAR 1289163 and up User Manual

Page 8

background image

OM--05688

0 SERIES

PAGE B -- 2

INSTALLATION

PREINSTALLATION INSPECTION

The pump assembly was inspected and tested be-
fore shipment from the factory. Before installation,
inspect the pump for damage which may have oc-
curred during shipment. Check as follows:

a. Inspect the pump and gearbox for cracks,

dents, damaged threads, and other obvious
damage.

b. Check for and tighten loose attaching hard-

ware. Since gaskets tend to shrink after dry-
ing, check for loose hardware at mating sur-
faces.

c. Carefully read all tags, decals, and markings

on the pump assembly, and perform all duties
indicated.Note the direction of rotation indi-
cated on the pump. Check that the pump
shaft rotates in the required direction.

Only operate this pump in the direction in-

dicated on the pump body and/or the ac-

companying decal. Reverse rotation of the

shaft will adversely effect pump perform-

ance, and the pump and/or gearbox could

be seriously damaged.

d. Check levels and lubricate as necessary. Re-

fer to

LUBRICATION in the MAINTENANCE

AND REPAIR section of this manual and per-
form duties as instructed.

e. If the pump and gearbox have been stored for

more than 12 months, some of the compo-
nents or lubricants may have exceeded their
maximum shelf life. These

must be inspected

or replaced to ensure maximum pump serv-
ice.

If the maximum shelf life has been exceeded, or if
anything appears to be abnormal, contact your
Gorman-Rupp distributor or the factory to deter-
mine the repair or updating policy.

Do not put the

pump into service until appropriate action has
been taken.

VEHICLE REQUIREMENTS

The following instructions apply equally to new in-
stallations, rebuilds or retrofits.

Tank Preparation

It is

essential that any tank scale, dirt, or other for-

eign material be removed from the tank and piping
prior to pump installation. Failure to do so could re-
sult in clogging or damage to the pump.

Damage to the pump resulting from debris

in the suction line

will not be covered by

the pump warranty.

Before connecting the suction and dis-

charge piping, carefully check the storage

tank and piping for construction debris

such as nuts, bolts, wire, weld slag, and

other foreign material. Install a commer-

cially available 80 mesh screen in the suc-

tion line to prevent debris from entering the

pump.

POSITIONING PUMP

Lifting

Pump unit weights will vary depending on the

mounting and drive provided. Check the shipping

tag on the unit packaging for the actual weight, and

use lifting equipment with appropriate capacity.

Drain the pump and remove all customer-installed

equipment such as suction and discharge hoses

or piping before attempting to lift existing, installed

units.

The pump assembly can be seriously

damaged if the cables or chains used to lift

and move the unit are improperly wrapped

around the pump.

Due to the confined mounting location,

specialized equipment such as a transmis-

sion jack with custom brackets should be