beautypg.com

Troubleshooting – Gorman-Rupp Pumps 06C1-GAR 1289163 and up User Manual

Page 17

background image

Check driver output; consult vehicle
operation manual.

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO

PRIME

Strainer clogged.

Check strainer and clean if neces-
sary.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace
leaking or worn seal or gasket.

Lining of suction hose collapsed.

Replace suction hose.

Air leak in suction line.

Correct leak.

PUMP STOPS OR

FAILS TO DELIVER

RATED FLOW OR

PRESSURE

Air leak in suction line.

Correct leak.

Strainer clogged.

Check strainer and clean if neces-
sary.

Pump speed too slow.

Suction intake not submerged at
proper level or sump too small.

Check installation and correct
submergence as needed.

Not enough liquid in cas-
ing.

Add liquid to casing. See
PRIMING.

Pump speed too slow.

Check driver output; consult vehicle
operation manual.

Lining of suction hose collapsed.

Replace suction hose.

OM--05688

0 SERIES

TROUBLESHOOTING

PAGE D -- 1

TROUBLESHOOTING --- SECTION D

Review all SAFETY information in Section A.

Before attempting to open or service the
pump:
1. Familiarize yourself with this manual.
2. Switch off the vehicle ignition and re-

move the key, or take other precau-
tions to ensure that the pump will re-
main inoperative.

3. Allow the pump to cool if overheated.
4. Check the temperature before open-

ing any covers, plates, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cautiously.
7. Drain the pump.