Filters, Filtros, Filtres – ProTeam ProForce 1500 HEPA User Manual
Page 9
FILTERS
CHANGING INTERCEPT MICRO FILTER
NOTE: Check and change Intercept Micro Filter
frequently! (Figure A)
1. To open the filter bag cover, press the release
button on top of the bag cover and open
cover.
2. Remove the used Intercept Micro Filter from
the vacuum and discard. Do not reuse bag.
3. Insert the new Intercept Micro Filter.
4. Close the cover and snap into place.
CHANGING MOTOR INTAKE FILTER
The motor intake filter is located under the
Intercept Micro Filter.
1. Remove the Intercept Micro Filter, then lift the
motor intake filter from the filter bag housing.
(Figure B)
2. Wash the motor intake filter in warm, soapy
water, rinse, and let AIR DRY.
3. Replace the motor intake filter, then the
Intercept Micro Filter.
4. Close the cover and snap into place.
CHANGING HEPA FILTER
1. Remove the HEPA filter cover. Press the release
latch and pull from vacuum (Figure C).
2. Remove the old HEPA filters.
3. Insert the new HEPA filters into cover. DO NOT
REUSE HEPA FILTERS.
4. Clean or dust filter cover and replace.
MAINTAINING THE FILTERS
HINT: Protect your motor! Keep your filters
clean.
CHECK:
• Intercept Micro Filter before you vacuum
• Intercept Micro Filter after you vacuum
• Motor Intake Filter alternating when you
change Intercept Micro Filter.
• HEPA Filter alternating when you change
Intercept Micro Filter
Always place switch in OFF, or “O” position,
and unplug cord from outlet before changing
filters or clearing obstructions.
FILTROS
CAMBIO DE LA BOLSA DE MICRO FILTRO
NOTA: ¡Revise y cambia la bolsa del micro filtro
con frecuencia! (Figura A)
1. Para abrir la cubierta de la bolsa del filtro, pre-
sione el botón y abra la cubierta.
2. Retire la bolsa del micro filtro de la aspiradora y
bótela. No reutilice la bolsa.
3. Inserte la nueva bolsa del micro filtro.
4. Levante la cubierta y ajústela bien.
CAMBIO DEL FILTRO DE ENTRADA DEL MOTOR
El filtro de entrada del motor está localizado
debajo de la bolsa del micro filtro.
1. Retire la bolsa del micro filtro, saque el filtro de
entrada del motor del compartimiento de la
bolsa del filtro. (Figura B)
2. Lave el filtro de entrada del motor en agua
jabonosa tibia, enjuague y DEJE SECAR
COMPLETAMENTE.
3. Vuelva a colocar el filtro de entrada del motor y
luego la bolsa del micro filtro.
4. Cierre la cubierta y ajuste bien.
CAMBIO DEL FILTRO
1. Quite la cubierta del filtro del escape. Prensa
libere trampa y levantar la aspiradora. (Figura C)
2. Quite el filtro de escape usado.
3. Inserte el Nuevo filtro de escape. NO REUTILICE
EL FILTRO.
4. Limpie o quite el polvo la cubierta del filtro del
escape y reemplaza
MANTENIMIENTO DE LOS FILTROS
SUGERENCIA: Proteja su motor! Mantenga los
filtros limpios.
REVISE:
• El micro filtro antes de aspirar
• El micro filtro después de aspirar
• Alternar motriz de filtro de toma cuando
usted cambia bolsa Micro de filtro
• El filtro del escape que alterna cuando usted
cambia bolsa Micro de filtro
Coloque siempre el interruptor en la posición
de APAGADO u “OFF” y desconecte el cable del
tomacorriente antes de cambiar los filtros y lim-
piar las obstrucciones o atascos.
FILTRES
CHANGER LE FILTRE INTERCEPT MICRO
NOTE : Vérifiez et changer le filtre Intercept
Micro fréquemment! (Figure A)
1. Pour ouvrir le compartiment du filtre, appuyez
sur le bouton de déverrouillage sur le dessus du
couvercle.
2. Enlevez le filtre Intercept Micro et jetez-le. Ne
pas le réutiliser.
3. Insérer un nouveau filtre Intercept Micro.
4. Refermez le couvercle. Un clic vous indiquera
qu’il est bien fermé.
CHANGER LE FILTRE DE LA PRISE D’AIR DU
MOTEUR
Ce filtre est situé sous le filtre Intercept Micro
1. Retirez le filtre Intercept Micro puis enlevez le
filtre de la prise d’air du moteur. (Figure B)
2. Lavez le filtre dans de l’eau tiède savonneuse.
Rincez et laissez SÉCHER À L’AIR.
3. Replacez le filtre de prise d’air puis le filtre Inter-
cept Micro.
4. Refermez le couvercle. Un clic vous indiquera
qu’il est bien fermé.
CHANGER LE FILTRE D’ÉVACUATION HEPA
1. Enlever le couvercle-filtre d’évacuation. Appuyez
sur le bouton de déverrouillage (Figure C).
2. Enlevez le filtre HEPA.
3. Insérez un nouveau filtre HEPA. NE PAS RÉU-
TILISER LE VIEUX FILTRE.
4. Nettoyez ou époussetez le couvercle-filtre et
remettez-le en place.
ENTRETIEN DES FILTRES
CONSEIL: Protégez votre moteur! Gardez les
filtres propres.
VÉRIFIEZ:
• Le filtre Intercept Micro avant de passer
l’aspirateur
• Le filtre Intercept Micro après avoir passé
l’aspirateur
• Le filtre de la prise d’air du moteur lorsque
vous changez le filtre Intercept Micro
• Le filtre d’évacuation lorsque vous changez le
filtre Intercept Micro
Toujours mettre l’interrupteur à la position
Arrêt (OFF) ou O, et débrancher l’aspirateur
avant de changer les filtres ou de dégager les
blocages.
Figure A/
Figura A
Figure B/
Figura B
7
HEPA filter
Nuevo HEPA filtro
Nouveau filtre HEPA
HEPA cover
Filtro del escape
Couvercle-filtre
d’évacuation
Figure C/
Figura C