beautypg.com

Remote control, cont’d – Extron Electronics VSC 150 User Guide User Manual

Page 18

background image

VSC 150 • Remote Control

VSC 150 • Remote Control

Remote Control, cont’d

3-5

V

ertical filter (detail)

Select vertical filter

X2

(Dvt)

X2

d

X2

+ 64

Dvt

X2

Specific value

Select next higher vertical filter (Dhz + 1)

{ d

7B

+

64

Dvt

X2

Incr

ement up

Select next lower vertical filter (Dhz - 1)

}

d

7D

+

64

Dvt

X2

Incr

ement down

Encoder filter (detail)

Select encoder filter

X3

(Enc)

X3

e

X3

+ 65

Enc

X3

Specific value

Select next higher encoder filter (Enc + 1)

{ e

7B

+

65

Enc

X3

Incr

ement up

Select next lower encoder filter (Enc - 1)

} e

7D

+

65

Enc

X3

Incr

ement down

Memory

Save pr

eset

X4

,

X4

2

C

Spr

X4

Recall pr

eset

X4

.

X4

2E

Rpr

X4

Fr

eeze

Set Fr

eeze mode to On (freeze the displayed image)

F

46

Frz

1

Enable fr

eeze

Set Fr

eeze mode to Of

f (r

elease the displayed image)

f

66

Frz

0

Disable fr

eeze

Executive mode

Set Executive mode to On

X

58

Exe

1

Enable executive

Set Executive mode to Of

f

x

78

Exe

0

Disable executive

Firmwar

e version, part number & information r

equests, and r

eset

System r

eset

Esc

z

1B 7A 0D

Zap

Reset to factory default

Query firmwar

e version number

Q/q

51/71

V

er x.xx

Display firmwar

e version

Request part number

N/n

4E/6E

N60-312-01

Display VSC 150

’s part #

Request information

Command

=

I/i

49/69

(see

below)

Display status

Response =

Dhz

X1

Dvt

X2

Enc

X3

Frz

X5

Exe

X5

X2

=

V

ertical filtering level (1 thr

ough 3)

X3

=

Encoder filtering level (1 thr

ough 3)

X4

=

Memory pr

esets (1 through 3)

X5

=

1 = On, 0 = Of

f

Symbol definitions

=

CR/LF (carriage r

eturn/line feed)

=

CR (carriage r

eturn only)

•=

Space

X1

=

Horizontal filtering level (1 thr

ough 2)

3-4

Command/r

esponse table

Command description

Command

Response

Additional

ASCII

Hex

(VSC to host)

d

escription

Horizontal shift

Shift right one step

{

H

7B + 48

Hph +

Incr

ement up

Shift left one step

}

H

7D + 48

Hph

-

Incr

ement down

V

ertical shift

Shift down one step

{ /

7B

+

2F

Vph

+

Incr

ement up

Shift up one step

} /

7D + 2F

Vph

-

Incr

ement down

Horizontal size

Incr

ease horizontal size by one step

{

:

7B + 3A

Hsz +

Incr

ement up

Decr

ease horizontal size by one step

}

:

7D + 3A

Hsz -

Incr

ement down

V

ertical size

Incr

ease vertical size by one step

{ ;

7B

+

3B

Vsz

+

Incr

ement up

Decr

ease vertical size by one step

} ;

7D

+

3B

Vsz

-

Incr

ement down

Horizontal filter (detail)

Select horizontal filter

X1

(Dhz)

X1

D

X1

+ 44

Dhz

X1

Specific value

Select next higher horizontal filter (Dhz + 1)

{ D

7B + 44

Dhz

X1

Incr

ement up

Select next lower horizontal filter (Dhz - 1)

} D

7D + 44

Dhz

X1

Incr

ement down

Command description

Command

Response

Additional

ASCII

Hex

(VSC to host)

d

escription