beautypg.com

Extron Electronics PS 123 Flexible Conduit Adapter Kit User Manual

Page 2

background image

PS 123 Flexible Conduit Adapter Kit • Instruction Guide

2

5

.

Use a standard screwdriver to loosen the screws holding the hot and

neutral

wires

on the

side of the terminal block nearest the IEC plate (figure 3, below).

6

.

Unscrew the IEC connector ground wire from the ground wire nut on the bare metal bottom

of the PS 123 enclosure.

7

.

From the rear panel end, pull the IEC connector (figure 1) out of the enclosure.

8

.

Thread the 18-gauge power wires through the length of the electrical conduit tube.

Figure 3 — Terminal block and IEC wiring
9

.

Install the EMT adapter plate (figure 4) (with conduit attached) into the opening from which

you removed the IEC in step 7. Use the Phillips head screws (figure 1) that you removed in

step 2 to attach the EMT adapter plate.

10

. Slide the conduit nut (figure 4) over the bundle of wires exiting the conduit and onto the

conduit itself inside the PS 123. Hand-tighten the nut.

11.

Attach and screw down the hot and neutral wires exiting from the conduit to their

corresponding screws on the terminal block.

Figure 4 — Terminal block and conduit wiring

W

Ensure that you observe wire polarity. Figure 4 shows the location of the neutral and

hot poles on the mother board connector. The conduit wiring harness' neutral wire is
identified with a tag marked "N" (neutral).

12.

Attach the ground wire from the conduit to the PS 123's bare metal plate bottom, securing it

by reattaching the ground wire nut.

13.

Thread a tie wrap through the metal tab on the bare metal bottom of the PS 123, place all the

wires within its cradle, and zip the tie wrap over the bundle of wires.

14.

Ensure that the conduit nut from step 10 (figure 4, above) firmly secures the conduit EMT

adapter plate to the power supply.

15.

Use the six screws you removed in step 3 to secure the top cover of the PS 123 back onto its

bottom board (figure 2).

Tie Wrap

Neutral Terminal

Ground Wire Nut

Terminal Block

Conduit Nut

Hot Terminal

Metal Tab

Hot Terminal

Neutral Terminal

Ground Wire Nut

Terminal Block

Extron Electronics, USA

1230 South Lewis Street

Anaheim, CA 92805

Extron Electronics, Europe

Beeldschermweg 6C

3821 AH Amersfoort

Extron Electronics, Asia

135 Joo Seng Road, #04-01

PM Industrial Building

Singapore 368363

Extron Electronics, Japan

Kyodo Building

16 Ichibancho

Chiyoda-ku, Tokyo 102-0082

www.extron.com