beautypg.com

Extron Electronics PIP 444 Setup Guide User Manual

Installation and cabling features, Windows, Connections

background image

N

For full installation, configuration, and operation details, refer to the

PIP 422 and PIP 444 User’s Manual, available at

www.extron.com

.

This guide provides quick start instructions for an experienced installer to set up

and operate the Extron Picture-in-Picture Processors.

Installation and Cabling Features

50/60 Hz

100-240V 0.3A

RS-232/422

VIDEO

Y

C

R-Y

Y/VID

B-Y/C

1

R-Y

Y

B-Y

I

N
P
U
T
S

O
U
T
P
U
T
S

IN

OUT

G
E
N
L
O
C
K

R-Y

Y/VID

B-Y/C

2

R-Y

Y/VID

B-Y/C

3

R-Y

Y/VID

B-Y/C

4

3

1

6

2

5 *

*

4

3

*

2

3

2

3

2

* PIP 444 only

*

*

Connections

a

AC power connector

d

Output BNC connectors

(component video, S-video, and composite video)

b

Inputs 1 through 2 (PIP 422) or 4 (PIP 444)

e

(PIP 444 only) Genlock In and Out BNC connector(s)

configurable BNC connectors

(component video, S-video, or composite video)

c

Inputs 1 through 2 (PIP 422) or 4 (PIP 444) loop-through

f

RS-232/RS-422 DB9 connector

configurable BNC connectors

(component video, S-video, or composite video)

Step 1 — Mounting

Turn off or disconnect all equipment power sources. For tabletop use, affix the rubber feet.

For optional rack or under furniture mounting, secure the supplied rack mounting bracket

or optional furniture mounting bracket (see image at right) and mount the unit.

Step 2 — Video inputs

a

.

Input (top) connectors

— Connect up to

two (PIP 422) or four (PIP 444) component

video, S-video, or composite video input

devices to these BNC connectors. The figure

below shows how to connect the various

video formats.

N

Connect only one video format to each input.

You must configure each input to identify
the connected video format.

b

. Input loop-through (bottom) connectors

If desired, connect local monitors to these

female BNC connectors. The processor

buffers the video input and loops it out on

these connectors..

N

The processor does not alter the video signal between the input and the buffered loop-through in any way. The buffered loop-

through output is in the same format as the input.

Menu system operations

The PIP LCD menu system diplays status changes and it provides access

to menus that allow the adjustment of the image and its parameters. The

LCD normally cycles continuously through default screens that identify the

detected format of the inputs and the assigned standard of the output as shown on the

previous page.

Menu system navigation

Press the Menu button to activate the menu system and to scroll through the four (PIP 444)

or three (PIP 422) main menus. Press the Next button to move between the submenus of

a selected main menu, to activate a submenu for viewing or configuration, and to save a

selection. When in a submenu or when a Picture Adjustments button is selected, rotate the

Adjust

[

knob and Adjust

{

knob to scroll through the submenu options and select a setting.

• Input Configuration menu —

Select the video format each input (composite video,

S-video, or component video).

• Output Configuration menu —

Select the standard for the video output (NTSC,

NTSC 0 IRE, or PAL).

• Advanced Configuration menu —

Select the border and background colors, the

transition effect (cut, wipe, or dissolve), and priority for each window.

• Genlock Configuration menu (PIP 444 only) —

Configure the horizontal phase and subcarrier phase of the

Genlock feature.

Configure the inputs

1

.

Repeatedly press Menu until the LCD reads Input Config.

2

.

Press Next.

3

.

Rotate the Adjust

[

knob to select an input. The LCD shows the selected input in the message Input #n Fmt.

4

.

Rotate the Adjust

{

knob to select the format of the connected video input (Video, S-video, or YUV).

5

.

Repeat steps 3 and 4 for each connected input.

6

.

PIP 444 —

Press Menu > Menu > Menu > Menu (Menu 4 times) > Next to return the default display cycle.

PIP 422 —

Press Menu > Menu > Menu (Menu 3 times) > Next to return the default display cycle.

Configure the output

1

.

Repeatedly press Menu until the LCD reads Output Config.

2

.

Press Next.

3

.

Rotate either Adjust knob to select the output format (NTSC, NTSC 0 IRE, or PAL).

4

.

PIP 444 —

Press Menu > Menu > Menu (Menu 3 times) > Next to return to the default display cycle.

PIP 422 —

Press Menu > Menu (Menu twice) > Next to return the default display cycle.

Windows

®

-based PIP 422 and PIP 444 Control Program

The control program is on the Extron Software Products DVD. Run the program on a PC connected to the RS-232/RS-422

port on the processor (

f

, on page 1). The program must be installed and cannot be run from the DVD.

N

For details on installing and operating the program, refer to the

PIP 422 and PIP 444 User's Manual, available at

www.extron.com

.

68-828-50

Rev. A

01 10

PIP 422 and PIP 444 – Setup Guide

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

© 2010 Extron Electronics. All rights reserved.

R-Y

Component Video

Input

S-Video

Y

/VID

B-Y

/C

1

I

N
P
U

T
S

R-Y

Y

/VID

B-Y/

C

2

Composite Video

R-Y

Y/

VID

B-Y/C

3

Buffered

Loop-through

#8 Screw (4 Plcs)
Each Side

Optional Furniture Mounting Bracket

Supplied Rack Mounting Bracket

Mounting Screws
(2 Plcs)
Each Side

or

Power

on

2 sec.

Menu

NOTE

The PIP returns to the last active

main menu or submenu when you
press Menu.

20 sec.

20 sec.

20 sec.

20 sec.

20 sec.

Default

Cycle

Menu

2 sec.

Input

Config

Menu

Output

Config

Menu

Advanced

Config

Menu

Menu

Next

Input

Config

To exit menu

press NEXT

60-606 (607)

-01

FW ver. n.nn

Extron, Inc.

PIP 444 (422)

Genlock

Config*

*PIP 444 only

This manual is related to the following products: