Step 3 — Throughput Connections

NOTE: See the two fiber cable connection drawings below. You can connect the transmitter and one or more receivers

in one of three ways:

One way (transmitter to receiver) only, perform step 3a.

Two way (transmitter to receiver and return), perform steps 3a and 3b.

One way (transmitter to receiver) with daisy chain (receiver to receiver), perform steps 3a and 3c.

a.

Connect the fiber between the Tx port on the transmitter and the Rx port on the receiver.

b.

If you want the receiver to send return serial data (such as responses from a controlled device) to
the transmitter, connect a cable between the Tx port on the receiver and Rx port on the transmitter.

c.

If you want a receiver to daisy chain the optical signal to another receiver (up to 10 receivers in a
daisy chain):

Connect the Tx fiber cable on the receiver to Rx on another receiver.

Set each receiver to daisy chain mode. See

Normal and Daisy Chain Modes

, below.

From Transmitter

or Daisy-Chained

Receiver

Receiver

Receiver

Tx

Rx

Tx

Rx

3a

3c

Step 4 — PowerCage Configuration Port

If desired, connect a host device to PowerCage enclosure Configuration connector via
the 9-pin D to 2.5 mm mini jack TRS RS-232 cable that is included with the PowerCage
enclosure or available separately using part #70-335-01. Repeatedly press the Comm
Select button until the Comm LED lights for the slot where the transmitter or receiver is
installed. The protocol for this port is as follows:

9600 baud

no parity

8 data bits

1 stop bit

no flow control

Refer to the PowerCage FOX Tx/Rx User Guide for detailed information about using the
SIS commands and the Windows

®

-based FOX Extender program to set up and operate

the transmitter and receiver and to take advantage of the various adjustments and test
patterns available on the PowerCage FOX units.

Operation

After all receivers, the transmitter, and their connected devices are powered up, the
system is fully operational. If any problems are encountered, verify that the cables are routed and connected properly
and that all display devices have identical resolutions and refresh rates. If your problems persist, call the Extron S3 Sales &
Technical Support Hotline at the number shown below that is closest to you.

Normal and Daisy Chain Modes

The receiver operates on one of two modes:

Normal mode — The receiver outputs RS-232 and SIS commands and responses on its Tx LC connector.

Daisy chain mode — The receiver daisy chains its Rx connector input through to its Tx connector output.

Use SIS commands issued to the connected unit to toggle between normal and daisy chain modes. Connect a PC to the
Remote RS-232 port of either unit or to the Configuration port on the PowerCage enclosure and issue the following command:
66*0*n#
where:
n = 2 = enable daisy chain mode
n = 1 or 0 = disable daisy chain mode

NOTE: Up to 10 receivers, each in daisy chain mode, can be connected in a daisy chain to a single transmitter.

Receiver

Transmitter

Tx

Rx

Tx

Rx

and

3a

3b

COMM

1

POWER

ALARM

COMM

SELECT

CONFIG

Comm
Select
Button

Configuration
Port

Comm

LED

68-1911-51
Rev A
10 10

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

© 2010 Extron Electronics. All rights reserved.

www.extron.com

2

PowerCage FOX Tx/Rx DVI Plus Setup Guide (Continued)