7.
Feed the individual wires, in the correct order,
through the open front face of the plastic
guide and out through the individual holes at
the other side. The rear of the guide should
be seated against the end of the jacket and
braid.
8.
Cut the wires to 0.6 inch (15.2 mm) as shown
at right.
9.
Push the guide up, leaving 0.3 inch of the
wires exposed above the guide (see image
at right).
10.
Insert the guide and wires into the RJ-45
connector, making sure the wires pass the
crimping teeth of the connector.
NOTE: Ensure the wires are in the correct
order (see table on the previous page)
and the bottom of the connector is
next to the braid shield that was folded
under the cable in step 4.
11.
Insert the connector into the termination tool
and crimp it to secure the connector to the
cable. Use pliers to secure the connector
tabs around the cable and the ground.
NOTE: To ensure correct grounding
throughout the cable, the braid shield
(folded back in step 4) must make
contact with the shielded RJ-45
connector on both ends of the cable.
12.
If a strain relief is present, slide it forward to
cover the cable and the first 0.4 inch
(10.2 mm) of the RJ-45 connector.
13.
Test both ends of the cable for conductivity.
NOTE: If there is a need to re-terminate the
cable, cut off the terminated end of the
cable and repeat steps 2 through 12.