Installation Procedure

N

Follow all local fire and safety code requirements for installation and anchoring. Install the Priority Page Sensor in a UL-compliant

junction box with a cover to meet plenum rating requirements.

For detailed installation instructions, refer to the PoleVault Installation Guide (see www.extron.com)

The sensor must be placed close to and in series with the speaker.
1

. Open the top of the Priority Page Sensor (see the figure at right).

Priority Page Sensor Kit Installation Instructions

L

R

L

R

L

R

AU

X A

UDI

O

INP

UT

5

LIN

E OU

T

VL R

ECEIVE

R

PAGI

NG

SENSO

R

DO N

OT

GRO

UND

OR S

HOR

T

SPE

AKER

OUTPUT

S

1B RG

B

1A

RG

B

2B RG

B

2A

RG

B

3B RG

B

/VIDEO

4B

RG

B

/VID

EO

3A R

GB

4A RG

B

I
N

P
U

T
S

RS

-23

2 ML

C/IR

DC

VO

L

2/4/8 O

hms

AMPLIFI

ED

AU

DIO

OU

T

VO

L/M

UTE T

x R

x I

R

12V

10V

PO

WE

R

PLE

NUM RA

TE

D U

L 20

43

US

LIS

TED

17

TT

AU

DIO

/VID

EO

AP

PAR

ATU

S

®

RG

B

VIDE

O

OUTP

UT

S

CO

NT

RO

L

N15779

12V
5A M

AX

Ceiling Mounted
Paging Speaker

Paging System

Priority
Page
Sensor

Classroom

Admin Building

To Classroom
Paging Speakers

Sensor
Output

Paging
Sensor
Input

PoleVault Twisted
Pair Switcher

Extron
SI 26

Surface Mount
Speakers

The Priority Page Sensor kit is designed for use with all PoleVault

®

switchers that have a paging sensor input. When the Priority Page

Sensor senses a PA system broadcast, it sends a signal to mute the

switcher’s program audio output for the duration of the PA broadcast.
The parts included with the kit include:

Priority Page Sensor

35’ (10.6 m) plenum-rated shielded twisted pair cable

UL-compliant junction box with cable clamp and cover.

The Priority Page Sensor is plenum rated but must be
installed in a UL‑compliant junction box with a cover to
meet the plenum rating requirement. All cables to and from
the sensor must also be plenum rated.

N

The Priority Page Sensor works with 25 V or 70 V and

4/8 ohm PA systems. It was not designed for, and may

not work properly with two-way intercoms, or systems

that are IP-based or use digital clocks.

Priority Page Sensor Kit Overview

2

. Remove the outer protective jacket from the speaker cable to expose the

two individual wires from the position of the sensor to the speaker. Do

not remove the inner protective jackets that cover the individual wires.

3

. If a junction box is being used in a plenum space, attach the cable clamp

and ensure the sensor and all wires fit inside the box, as shown in the

figure below, right. All cables leaving the box must be plenum rated.

4

. Loop (only) one of the exposed speaker leads tightly around the top (open)

part of the sensor (as shown at right). Either speaker wire will work. Leave the

other speaker wire connected directly to the speaker. Polarity need not be observed.

• For a 25 V or 70 V system — wrap 5 to 8 loops.

• For a 4/8 ohm system — wrap 2 to 4 loops.

5

. Close and latch the top of the Priority Page Sensor.

6

. Connect the bare wire end of the supplied blue sensor cable to the 2-pole captive screw connector on the

Priority Page Sensor, passing it into the junction box, if necessary. Polarity need not be observed.

7

. Tighten the cable clamp and secure the lid to the junction box.

8

. Route the connector end of the blue sensor cable to the PVS switcher, and plug it into the Paging Sensor input.

9

. Enable the switcher’s paging sensor port, using Global Configurator or the MediaLink Switchers (MLS) and

PoleVault Switchers (PVS)

control software, available at www.extron.com

Testing and Adjustment Procedure

1

. Turn the program audio on.

2

. Speak into the PA system microphone. The program audio is muted while the PA system broadcast

occurs, and restored when the PA broadcast ends.

3

. If program audio is not muted during a PA broadcast, turn the Paging Sensitivity adjustment on the

PoleVault switcher clockwise.

4

. If program audio is muted without a page occurring, turn the Paging Sensitivity adjustment on the PoleVault

switcher counterclockwise.

Ceiling Mounted
Paging Speaker

Priority
Page
Sensor

Strip plenum jacket from
speaker cable to reveal
two speaker wires.

Speaker Cable with
Plenum Jacket Intact

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

68-1489-01

B

03 09

N

To prevent the program audio from being

restored prematurely due to a pause by the

announcer, you can set a time delay from

1 to 8 seconds via the switcher’s RS-232

interface. See the switcher’s User’s Manual.