Side
RJ-45
Connector
12345678
Insert
Twisted
Pair Wires
Pins:
NOTE: When the TP input is from a low resolution unit (MTP SV or MTP AV),
the signal assignment depends on the position of signal jumpers in
the transmitter and receiver (see the MTP AV Series User Guide).
Jumpers in Mono Position (Default)
Pin 568 A Wire
Color
568 B Wire
Color
Composite Video
MTP Signal
S-video
MTP Signal
RGB Video, MTP,
VTT/VTR Signal
1
White-
green
White-
orange
Reserved
Chroma (C) +
Red/
V.Sync +
2
Green
Orange
Reserved
Chroma (C) –
Red/
V.Sync –
3
White-
orange
White-
green
Mono audio +
Mono audio +
Mono audio + or
RS-232 +
(MTP 15HD only)
4
Blue
Blue
Video +
Luma (Y) +
5
White-blue
White-blue
Video –
Luma (Y) –
Green –
6
Orange
Green
Mono audio -
Mono audio –
Mono audio – or
RS-232 –
(MTP 15HD only)
7
White-
brown
White-
brown
Reserved
Reserved
Blue/
H.Sync +
8
Brown
Brown
Reserved
Reserved
Blue/
H.Sync –
Jumpers in Stereo Position
Pin 568 A Wire
Color
568 B Wire
Color
Composite Video
MTP Signal
S-video
MTP Signal
1
White-
green
White-
orange
Video +
Luma (Y) +
2
Green
Orange
Video –
Luma (Y) –
3
White-
orange
White-
green
Reserved
Reserved
4
Blue
Blue
Audio left +
Chroma (C) &
audio left +
5
White-blue
White-blue
Audio left –
Chroma (C) &
audio left –
6
Orange
Green
Reserved
Reserved
7
White-
brown
White-
brown
Audio right +
Audio right +
8
Brown
Brown
Audio right –
Audio right –
NOTE: If you are using Enhanced Skew-Free™ AV cable, use the
TIA/EIA T 568A standard only.
Figure 6.
TP Cable Termination
MTP DA4 and MTP DA8 • Installation and Operation
9