Installation and operation, Connections – Extron Electronics MTP DA8 User Guide User Manual
Page 12
Installation and
Operation
This section provides information pertaining to the installation and operation of the
MTP DA4 and MTP DA8, including:
•
•
•
•
•
Connections
ATTENTION: Do not connect these devices to a computer data or telecommunications
network.
MTP DA4
1
2
3
4
1 2 3 4 A
OUTPUT MUTE
12V
POWER
+
-
MTP DA8
A/V INPUT
1
2
3
4
5
6
7
8
1 2 3 4 5 6 7 8 A
OUTPUT MUTE
0.93A MAX
12V
POWER
+
-
A/V OUTPUTS
A/V INPUT
0.93A MAX
A/V OUTPUTS
1
2
3
4
1
2
3
4
Figure 3.
MTP DA Rear Panel Features
a
Power connector — Plug the included external 12 VDC power supply into this 2-pole
captive screw connector (see
on page 7 to wire the connector).
b
AV Input connector — Connect one end of the cable carrying the video or
audio/ serial TP link from the transmitting device to this RJ-45 female connector (see
on page 8 to wire the RJ-45 connectors).
c
AV Output connector — Connect one end of up to four or eight TP cables to these
RJ-45 female connectors.
Connect the free ends of the same cables carrying the distributed video or audio/serial
TP link to the RJ-45 connectors on the receivers (see
to wire the RJ-45 connectors).
6