Configuring the mps 601, Setup and operation, Connect power – Extron Electronics MPS 601 Setup Guide User Manual
Page 3
3
ATTENTION:
•
Always use a power supply provided by or specified by Extron. Use
of an unauthorized power supply voids all regulatory compliance
certification and may cause damage to the supply and the end
product.
•
Unless otherwise stated, the AC/DC adapters are not suitable for
use in air handling spaces or in wall cavities. The power supply is
to be located within the same vicinity as the Extron AV processing
equipment in an ordinary location, Pollution Degree 2, secured to the
equipment rack within the dedicated closet, podium, or desk.
•
The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and
the Canadian Electrical Code part 1, section 16. The power supply
shall not be permanently fixed to building structure or similar structure.
Connect Power
Connect the provided 12 VDC power supply to the rear panel captive screw connector (see figure 1,
a
). and plug the AC power
cord into 100-240 VAC, at 50-60 Hz.
DC Power Cord
Captive Screw
Connector
AC Power Cord
External
Power Supply
(12 VDC, 1 A )
Ground
+12 VDC
3/16"
(5 mm) Max.
Figure 5.
Power Supply Wiring
Configuring the MPS 601
The MPS 601 can be configured using a connected PC and the Extron Product Configuration Software or using SIS commands.
To configure the MPS 601 using the Product Configuration Software, install the software (available on the Extron website,
www.extron.com
) on a PC connected to the MPS 601 by the rear panel remote (RS-232) port (see figure 1,
h
), or front panel
USB Config port (see figure 6,
b
). After the installation, start the program. See the
MPS 601 User Guide and the Product
Configuration Software Help File for additional information.
To configure the MPS 601 using SIS commands, see the
MPS 601 User Guide.
MPS 601
MEDIA PRESENTATION SWITCHER
CONFIG
SIGNAL
INPUTS
INPUTS
OUTPUT
1
2
3
4
5
6
HDCP
1
2
3
4
5
6
AUTO
SWITCH
a b
f
c
d
e
g
Figure 6.
MPS 601 Front Panel
Setup and Operation
a
Power on all connected devices, then apply power to the MPS 601. The Auto Switch LED lights when auto-input switching is
active.
b
One mini type-B female USB Config port connects to a host computer for configuring the switcher and upgrading firmware.
c
Input switching. The input group has six buttons with associated green LEDs. Press an input button to switch the input to the
HDMI output. The associated LED lights. Only one of the six inputs can be selected at a time.
d
Input signal LEDs. Six green LEDs indicate:
•
The LEDs for RGBHV inputs 1 and 2 light when horizontal sync is detected on the input.
•
The LEDs for HDMI inputs 3 to 6 light when TMDS clock activity is detected on the input.
NOTE: If a connected HDMI source is HDCP encrypted, the associated input signal LED does not light until HDCP is
authenticated.