Extron Electronics Fiber Optic Cables Cleaning User Manual
Fiber optic cables • cleaning instructions, Connectors, Fpm/fls 101 adapters
Fiber Optic Cables • Cleaning Instructions
Optimum optical performance is obtained when the reference cable connectors and the
FPM/FLS 101 adapters are properly cleaned. Perform the following procedures prior to use.
WARNING: Always handle, use and dispose of chemicals in accordance with
manufacturer’s safety instructions. Some chemicals may be toxic if swallowed.
Connectors
1.
Moisten a lint-free wipe with alcohol (damp, but not saturated), or use a pre-moistened
wipe.
2.
Wipe the ferrule end-face in a twisting/wiping motion.
3.
Repeat twice, using a clean area of the dampened wipe each time.
4.
Repeat wiping action using a dry lint-free wipe.
5.
Inspect the end-face under magnification (100x minimum) to ensure debris and
contaminants are removed.
FPM/FLS 101 Adapters
1.
Moisten the end of a lint-free swab with alcohol.
2.
Remove excess alcohol from the swab with a dry, clean wipe.
3.
Insert the swab into either end of the adapter.
4.
Clean, using a scrubbing motion.
5.
Remove the swab using a rotating motion.
6.
Using clean, compressed air, blow out the adapter until dry.
WARNING: Always wear eye protection when using compressed air. Never inspect or
look into the end of terminated fibers as invisible laser radiation may damage eye
tissue.
68-2103-01
Rev.
A
04 11
Equipment and Supply Requirements
The following items are recommended for cleaning the reference cable.
Isopropyl
Alcohol
Lint-free
Optical Wipes
or
Microfiber
Woven Wipes
Pre-moistened
Towelette
Oil-free
Compressed Air
Lint-free
Swabs
Magnifier