Configuring the Scaler

Configuring the scaler:

Press the input and rate buttons simultaneously, and hold them for two

seconds.

Stepping through the LCD display menus:

Press the input button.

Changing a selection:

Turn the adjustment knob while the menu is displayed.

Exiting the menus:

Press the input button while the Detail menu is displayed, or don’t press any

buttons or turn any knobs for eight seconds.

AUTOSW —

Choose whether the DVS automatically selects the active input.

On

: The scaler selects the active input automatically. Off: You select the input manually.

TOPBLANK —

Add or remove additional blanking lines at the top of the image.

BOTBLANK —

Add or remove additional blanking lines at the bottom of the image.

H-SYNC —

Change the polarity of the horizontal sync signal to allow any projector to distinguish the

DVS 150 input from a standard RGB input.
+

: Sets the horizontal sync polarity to positive. -: Sets the horizontal sync polarity to negative.

V-SYNC —

Change the polarity of the vertical sync signal to allow any projector to distinguish the

DVS 150 input from a standard RGB input.
+

: Sets the vertical sync polarity to positive. -: Sets the vertical sync polarity to negative.

SOG —

Set the sync output format.

Yes

: Sync on green (RGsB) output. No: RGBS or RGBHV output (based on unit cabling).

STILL —

Enhance output for still or motion video.

On

: Enhanced image for still video and text. Off: Enhanced image for motion video.

DETAIL —

Apply a filter to improve image detail.

1

: Low level of detail. 2: Medium level of detail. 3: High level of detail.

Operation

Choosing the input source:

Press and release the input button until the desired input LED lights.

If input 4 (RGB pass-through) is selected, you cannot make any of the following adjustments.

Adjusting the image:

Press the button for the adjustment, and rotate the adjustment knob until the

desired result is achieved.

Choosing the output rate:

Press and hold the rate button for two seconds, and then rotate the

adjustment knob until the desired rate appears in the LCD display. Options are:

640x480 (VGA), 60/75 Hz

848x480 (plasma), 60 Hz

1280x768 (plasma), 56 Hz 480p (HDTV)

800x600 (SVGA), 60/75 Hz 852x480 (plasma), 60/75 Hz

1280x1024 (SXGA), 60 Hz 720p (HDTV)

832x624 (Mac), 60/75 Hz

1024x768 (XGA), 60/75 Hz

1360x765 (plasma), 60 Hz 1080p (HDTV)

Activating freeze mode:

Issue the RS-232 freeze mode command.

Deactivating freeze mode:

Press the input button or issue an RS-232 command.

Restoring default picture control settings (active input):

Press and hold the input button for

two seconds.

Restoring all settings to factory defaults:

Press and hold the input button while attaching the AC

power cord.