beautypg.com

Control software for windows, Installing the software – Extron Electronics DVS 150 User Manual

Page 27

background image

4-5

DVS 150 Serial Communication

COMMAND

ASCII

RESPONSE

DESCRIPTION

Vertical shift

Specific value

X2

/

Vph

X2

Selects vertical shift

X2

Increment up

{/

Vph+

Shift image up one step

Increment down

}/

Vph–

Shift image down one step

Set output rate

X3

=

Rte

X3

Set the video output rate

Freeze

Enable

F

Frz 1

Set freeze mode to On (freeze current displayed image)

Disable

f

Frz Ø

Set freeze mode to Off

Executive mode

Enable

X

Exe 1

Set executive mode to On

Disable

x

Exe Ø

Set executive mode to Off

Query software version

q

(Same as Q below)

Q

Ver x.xx

Example response: Ver 3.2

Still mode

X4

#

Stl

X4

Sets still mode On or Off

Detail mode

X6

D

Det

X6

Sets detail mode to level 1 (low), 2, or 3 (high)

Request part number

n

(Same as N below)

N

N6Ш-317-Ш1

Displays the Extron part number

Request information*

i

(Same as I below)

I

C

X1

•Col

X2

•Tin

X2

•Con

X2

•Brt

X2

•Hph

X2

•Vph

X2

•Rte

X3

•Frz

X4

•Exe

X4

•Typ

X5

•Stl

X4

•Det

X6

*

Typ

X5

displays the type of input video signal as automatically sensed by the scaler. You cannot change this

entry.

Control Software for Windows

The Signal Enhancement Products Control Program (part # 29-017-01), which is used
by the scalers, is compatible with Windows 3.1, 3.11, 95/98, and NT. It provides
remote control of scaler settings. Use version 3.2 or later.

Installing the software

The program is contained on a single 3.5-inch diskette, and it can run from the
floppy drive. However, it is usually more convenient to load and run the program
from the hard drive.

To install the software from the floppy disk onto the hard drive, run SETUP.EXE
from the floppy disk, and follow the instructions that appear on the screen. The
program occupies approximately 1 MB (megabyte) of hard-drive space.

By default, the Windows installation creates a C:\S_ENHANC directory, and it
places two icons (Signal Enhancement Products Control Pgm and Signal
Enhancement Products Help) into a group or folder named “Extron Electronics”.