Mounting faceplates in the floor box, 3akm uk series • installation guide – Extron Electronics AKM UK Series User Manual
Page 3

3
AKM UK Series • Installation Guide
Mounting Faceplates in the Floor Box
To mount the AKM UK faceplates:
1.
Turn off all devices and disconnect them from the power source.
2.
Install the faceplate into the floor box as follows:
a.
Insert the faceplate into the floor box so that the flange for the
#4-40 x 5/16" screw (smaller screw hole) fits under the floor box frame.
b.
Allow the other flange to rest on top of the floor box frame on the
opposite side. Line up the screws holes on the flanges and frame.
You may have to remove the floor box lid to insert and tighten the
#4-40 x 5/16" screws. This is not necessary if the lid is installed on the self-
tapping screw hold side, as shown in the figure on this page.
3.
Using the small (#4-40 x 5/16") screw, attach the faceplate flange to the
underside of the floor box frame.
4.
Using the larger (#6-32 x 1/2") screw, attach the other faceplate flange to the
floor box frame.
5.
Repeat steps 1 to 4 to install other faceplates.
6.
Restore power to all devices.
#4-40 x 5/16 Screw
#6-32 x 1/2
Self-tapping Screw
Self-tapping
Screw Holes
EX