Lighting instructions white - rodgers gas controls – John Wood Commercial - ANED User Manual
Page 13
Page 12
LIGHTING INSTRUCTIONS
WHITE - RODGERS GAS CONTROLS
1. STOP! Read the safety information at the head of this
section.
2. Set the thermostat to lowest setting. (Rotate dial
clock-wise).
3. Depress gas control slightly and turn clock-wise to
“OFF”. If knob is in “ON” position, turn clock-wise to
“PILOT” then
depress knob slightly and turn
clock-wise to “OFF”.
4. Wait five (5) minutes to clear out any gas. If you smell
gas, STOP! Follow “B” in the safety information at the
head of this section. If you don’t smell gas, go to the next
step.
5. Remove burner access cover located below the gas
control unit.
6. Find pilot - follow small metal tubes from gas control. The
pilot is located between the two centre burners.
7. Turn knob on gas control knob counter-clock-wise
to “PILOT”
8. Depress control knob all the way and hold in. Immediately
light the pilot with a match. Continue to hold the control
knob down for about 1 minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain lit. If it
goes out, repeat steps 3,4,7 and 8.
If knob does not pop up when released, turn clock-wise to
“OFF”, stop and immediately call your service
technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob “OFF” and call your service technician or gas
supplier.
9. Replace burner access cover.
10.Turn gas control knob counter-clock-wise to “ON”
position.
Set the thermostat to desired setting clock-wise.
To Turn Off Gas To Appliance
1. Set the thermostat to lowest setting.
2. Turn the gas control knob clock-wise to
“PILOT”
3. Depress gas control knob slightly and turn clock-wise to
“OFF”. Do not use tools or excessive force.
BEFORE LIGHTING, SNIFF AT FLOOR LEVEL. IF
YOU SMELL GAS, FOLLOW THESE RULES:
1. Get all people out of the building.
2. DO NOT light matches.
3. DO NOT TOUCH electrical switches (on or off)
4. DO NOT use an electric fan to remove gas from
area.
5. SHUT OFF GAS at the LP tank outside of the
building.
6. IMMEDIATELY call the LP Gas Company or the fire
department from a neighbour’s telephone. Ask for
instructions, before hanging up, give your name,
address and telephone number.
7.
DO NOT go back into the building. If help is coming, wait
for it outside of the building.
GAS CONTROL KNOB
(OFF-PILOT-ON)
TEMPERATURE
DIAL
WARNING:
Should overheating occur, or the gas supply
fail to shut off, turn the manual gas control to the
appliance to “OFF”.
WARNING:
HOTTER WATER INCREASES THE RISK
OF SCALD