background image

ELECTRONIC IGNITION MODELS:

ROBERTSHAW IGNITION MODULE AND VALVE

SCHEMATIC DIAGRAM

L1 (HOT)

120 VAC

L2 (NEU.)

L3 (GND)

24 VOLT TRANSFORMER

MOTOR

SERV.

SWITCH

R1(N.C.)

NORMAL
POSITION

S.S.1
(N.O.)

ECO

TH.ST

2

3

4

1

DAMPER
DRIVE
FLAIR-SL

QUICK
CONNECT

RELAY
COIL

CHASSIS
GROUND

GAS VALVE

TR

TH

ROBERTSHAW CONTROL MODULE
SP745

MV

TH

PV/MV

TR

GND

PV

ING

HIGH VOLTAGE
LEAD

SPARK
ELECTRODE

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED MUST BE
REPLACED. USE ONLY TYPE 105

O

C THERMOPLASTIC OR EQUIVALENT.

EXCEPT THE SPARK IGNITION CABLE WHICH MUST BE HIGH VOLTAGE 450

O

C

FACTORY INSTALLED WIRES

BY INSTALLER

Page 9

R2 (N.O)
S.S.2 (N.C)

E.S. (N.O.)