Warning For Installations
FOR YOUR SAFETY, READ
BEFORE INSTALLATION
Do not install the heater
where water, debris or flam-
mable vapors may get into
the flue terminal. This may
cause damage to the heater
and void the warranty.
Do not have the vent ter-
minal pointing toward any
opening into a building. Do
not locate your heater in a
pit or location where gas
and water can accumulate.
Do not install next to a dryer
or any source of airborne
debris that can be trapped
inside the combustion
chamber, unless the system
is direct vented.
•
High-altitude Installations
Check the elevation where your water heater is installed.
Set DIPswitches shown in the table below depending on the
altitude. These DIPswitches (No. 5 and No. 6) are on the
computer board on the left bank only.
Altitude
0 to 2,500 ft
(default)
2,500 to
4,000 ft
4,000 to
5,000 ft
Over
5,000 ft
Switch
No.5
OFF
ON
OFF
Consult our
Technical
Services
Department
at 1-888-
479-8324
Switch
No.6
OFF
OFF
ON
10
9
8
7
6
5
4
3
2
1
ON
10
9
8
7
6
5
4
3
2
1
ON
10
9
8
7
6
5
4
3
2
1
ON
The dark squares indicate the direction the DIPswitches
should be set to.
DO NOT
adjust any DIPswitches on the right bank.
Left bank of
DIP switches