(For Intake: 76mm (3 in.) only)

Connect a 102mm (4 in.) PVC Straight pipe directly on
the intake vent collar of the water heater.
Connect a 4x3" PVC reducer to the 102mm (4 in.) PVC
Straight pipe.
From the reducer, continue on the rest of the vent run
with 76mm (3 in.) PVC pipe.

76mm (3 in.) PVC
straight pipe

76mm (3 in.) PVC

straight pipe

4x3" PVC
reducer

TH-PA01 PVC
adaptor*

Exhaust vent collar of
the 520H (Female)

Intake vent collar

* TH-PA01 PVC adaptor
is included with the 520H.

4x3" PVC
reducer

1026mm (4 in.)

PVC straight pipe

1.

2.

3.

Stainless steel Venting Illustrations
Horizontal Installation Diagram

Wall

Sidewall Vent

Terminator

Vertical Installation Diagram

Roof

Fire stop

Rain Cap

Roof Flashing

Regarding the clearances from the exhaust terminator to
the air inlet or opening, refer to the next few pages.
Follow all vent system manufacturer’s instructions and
all local codes.
Do not common vent or connect any vent from other
appliances to the 520H water heater vent.
Use 102mm (4 in.) Category III/IV approved or Special
BH, single or double wall stainless steel vent pipe.