beautypg.com

John Wood Takagi - 320H-520H User Manual

Page 12

background image

12

Vent clearances

INSIDE CORNER

DET

AIL

FIXED

CLOSED

OPERABLE

FIXED

CLOSED

OPERABLE

Vent terminal

Air supply inlet

Area where is not permitted

Gas meter / regulator

Canada

U.S.A

Direct vent and other

than Direct Vent

Direct

vent

Other than

Direct Vent

A

Clearance above grade, veranda, porch, deck, or balcony.

1 foot

1 foot

1 foot

B Clearance to window or door that may be opened

3 feet

1 foot

4 feet from below or

side opening. 1 foot

from above opening.

C

Clearance to permanently closed window

*

*

*

D

Vertical clearance to ventilated soffit located above the
vent terminator within a horizontal distance of 2 feet
(61cm) from the center line of the terminator.

*

*

*

E

Clearance to unventilated soffit

*

*

*

F

Clearance to outside corner

*

*

*

G

Clearance to inside corner

*

*

*

H

Clearance to each side of center line extended above
meter/regulator assembly

3 feet

*

*

I

Clearance to service regulator vent outlet.

3 feet

*

*

J

Clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other application

3 feet

1 foot

4 feet from below or

side opening. 1 foot

from above opening.

K

Clearance to mechanical air supply inlet.

6 feet

3 feet

3 feet

L

Clearance above paved sidewalk or paved driveway
located on public property.

7 feet

*

7 feet

M

Clearance under veranda, porch deck, or balcony.

1 foot

*

*

* For clearances not specified in CSA-B149.1, please use clearances in accordance with local installation codes and

the requirement of the gas supplier.