Caution, Maintenance – John Wood Superflue Power Vent (before FVIR technology) User Manual
Page 18
-16-
Keep the area around the heater clear
and unobstructed.
Keep safety your first priority. Take all
precautions to avoid creating a fire,
health or safety hazard.
Although this heater has been specifically approved for certain clearances to combustible materials, any objects
placed in that space will reduce air circulation and increase the risk of fire.
CAUTION
WARNING
VIII) COMBINATION POTABLE WATER
HEATING AND SPACE HEATING
(COMBO)
This section serves as a guide for the installation and use of
“Combo” heating systems utilizing a domestic water heater which
has been specifically approved for such use. It is written for those
knowledgeable in the required trades and professionals involved
in the design and installation of Combo Heating Systems.
It is the responsibility of the installer/ designer to fol-
low all applicable codes to ensure the effectiveness
and safety of the installation.
Caution
READ BEFORE PROCEEDING
The following requirements must be met for the installation of
Combo Heating Systems:
1.All components used for the distribution of water in the heating
loop must be suitable for potable water. These include all piping,
fittings, solder and fluxes, pumps for circulation of water, valves,
etc.
2.The water heater must not be connected to a hydronic heat-
ing system that has been used previously.
3.No boiler treatment chemicals of any kind shall be introduced
into the system.
4.The Combo System components must be selected and sized to
meet and maintain the total calculated demands for both domes-
tic service hot water and space heating requirement. The sizing
and installation must be performed in accordance with good engi-
neering practice such as ASHRAE Handbooks, HRAI, Hydronics
Institute Manuals, CGA B149, NFPA 54, ANSI Z223.1, CSA F280,
National/Provincial Building Codes, CSA C22.1, ANSI/NFPA 70,
CSA B51 and/or codes having jurisdiction.
5.The air handler (fan coil) and/or the circulating pump in a base-
board hydronic loop will require a dedicated 120V circuit. This
must be provided and identified for this purpose.
6.All piping between the water heater and the air handler or
hydronic baseboard loop must be adequately insulated to reduce
heat loss.
7.If the local jurisdiction requires a back-flow preventer in the cold
water line, an expansion tank of adequate size must be installed.
8.To reduce the scald hazard potential, a mixing valve must be
installed.
INSTALLATION
The heating mode may be one of the following options:
A- A fan coil/air handler (figure 16).
B- A hydronic baseboard (finned tube) loop/ In floor heating (fig-
ure 17).
The following is a list of requirements for the installation of the
heating loop to the water heater.
a)Install shut-off valves and unions so that the water heater can
be isolated from the heating module should servicing of the water
heater become necessary.
b)Install a drain valve at the lowest point of the heating loop so
that water can be drained from the heating module without affect-
ing the water heater.
c)If the air handler does not have a venting means at the highest
point of the piping arrangement, install an air bleed at the highest
point of the plumbing arrangement.
MAINTENANCE
The installation and maintenance of the water heater must follow
all of the instructions described in sections I to VII of this manual.
Heater failure that is a result of the heating system is not covered
by warranty.
Figure 16
Figure 17
BASEBOARD PIPING OF
GSW POWER-VENT
GAS-FIRED WATER HEATER
(SIDE-TAPPED)
SIDE-TAPPED PIPING OF GSW
POWER-VENT GAS-FIRED WATER
HEATER (INTERNAL OR EXTERNAL
CIRCULATOR)
IF USED CHECK VALVE
REQUIRE EXPANSION TANK
IF USED CHECK VALVE
REQUIRE EXPANSION TANK
(OPTIONAL)
(OPTIONAL)
(OPTIONAL)
(OPTIONAL)
RETURN
RETURN
SUPPLY
SUPPLY
WATER HEATER
WATER HEATER
HOSE BIB
HOSE BIB
CIRCULATOR
FLOW CONTROL
FLOW CONTROL
EXTERNAL
CIRCULATOR
INTERNAL
CIRCULATOR
EXPANSION TANK
EXPANSION TANK
CHECK
VALVE
CHECK
VALVE
DRAIN/
PURGE
VALVE
MIXING-
VALVE
MIXING-
VALVE
8 in TO 12 in
MAX.
8 in TO 12 in
MAX.
HOT W
A
TER
T
O
HOUSE FIXTURE
HYDRONIC BASEBOARDS
(SERIES CONNECTED SHOWN)
COLD
SUPPLY
COLD
SUPPLY
HOT
OUTLET
COLD
INLET
HOT W
A
TER
T
O
HOUSE FIXTURE
HOT
OUTLET
AIR HANDLER
COLD
INLET