15
Commands and Functions
Optionally used as part of an IF statement to indicate another condition to evaluate. The option is
evaluated if all previous options have resulted in FALSE. Multiple ELSEIF conditions may be tested
If the condition evaluates to TRUE, all following conditions will not be tested.
var = DATETIME(MINUTES)
sync = 0
IF (var == 0) THEN
sync = 1
ELSEIF (var == 15) THEN
sync = 2
ELSEIF (var == 30) THEN
sync = 3
ELSEIF (var == 45) THEN
sync = 4
ELSE
sync = -1
ENDIF
ELSEIF
Immediately ends the Basic program. Optional if used as the last statement.
var = DATETIME(MINUTES)
IF (var == 0) THEN
REM if top of the hour, end the program
END
Declares the end of a multi-line IF-THEN statement. Not required on single-line if statements.
var = DATETIME(MINUTES)
sync = 0
IF (var == 0) THEN
sync = 1
ELSEIF (var == 30) THEN
sync = 2
ELSE
sync = -1
ENDIF
ENDIF
- H-2191 (57 pages)
- H-223 (9 pages)
- H-264 (16 pages)
- H-310 (40 pages)
- H-312 (38 pages)
- H-3301 (24 pages)
- H-3342 (30 pages)
- H-335 (32 pages)
- H-339 (21 pages)
- H-340-CalKit (6 pages)
- H-340 (12 pages)
- H-340SDI (32 pages)
- H-3521 (57 pages)
- H-3531 FlashLite (76 pages)
- H-3551 (42 pages)
- H-3553 (36 pages)
- H-375 04101 WIND MONITOR-JR (18 pages)
- H-4161 (36 pages)
- H-4191 (21 pages)
- H-424MS V1.0 (25 pages)
- H-424MS V1.1 (22 pages)
- H-4271 (22 pages)
- H-4280 (34 pages)
- H-4400 (7 pages)
- H-4401 (6 pages)
- H-5223 (107 pages)
- STORM 3 UPGRADE (4 pages)
- System 5000 BASIC Manual (54 pages)
- System 5000 User Manual (136 pages)
- DH-21 (112 pages)
- BrazedPlate Heat Exchangers (4 pages)
- Heat Exchangers (8 pages)
- GL500 MULTICHANNEL DATA LOGGER (32 pages)
- 4046 ANALOG TO SDI-12 CONVERTER (7 pages)
- 4015 SDI-12 TO ANALOG CONVERTER (5 pages)
- iRIS-CAM Wastewater Security Camera (11 pages)
- SDI-12 Data Logger iRIS 220, iRIS 320, iRIS 350, iRIS 150, iRIS 300 (111 pages)
- iRIS 150 GPRS DATALOGGERS (53 pages)
- iCE3 GPRS Variant (29 pages)
- GL500-2-1 Data Logger (32 pages)
- 3101 CONDUCTIVITY CONTROLLER (11 pages)
- 3675 pH CONTROLLER (9 pages)
- 378 TEMPERATURE CONTROLLER (9 pages)
- Expert 1400 (16 pages)
- Expert 700 (8 pages)