beautypg.com

Maintenance, Disassembly, Disassembly precautions – Xylem P2000799B Series e-90 Close-Coupled In-Line Centrifugal Pumps User Manual

Page 17: Drain the pump, Disassembly precautions drain the pump

background image

Maintenance

Disassembly

Disassembly precautions

This manual clearly identifies accepted methods for disassembling units. These methods
must be adhered to.

WARNING:

• Make sure that the pump is isolated from the system and that pressure is relieved

before you disassemble the pump, remove plugs, open vent or drain valves, or
disconnect the piping.

• Always disconnect and lock out power to the driver before you perform any

installation or maintenance tasks. Failure to disconnect and lock out driver power will
result in serious physical injury.

• Crush hazard. The unit and the components can be heavy. Use proper lifting methods

and wear steel-toed shoes at all times.

• After you disassemble a gasket joint, always use a new gasket upon reassembly.

Never reuse old gaskets. Failure to follow these instructions can result in serious
personal injury, death, and/or property damage.

• Trapped liquid can rapidly expand and result in a violent explosion and injury. Never

apply heat to impellers, propellers, or their retaining devices to aid in their removal.

NOTICE:
Make sure that all replacement parts are available before you disassemble the pump for
overhaul.

Drain the pump

CAUTION:

• Allow all system and pump components to cool before you handle them to prevent

physical injury.

1. Disconnect the electrical supply and lock it out of service.
2. Loosen the conduit box cover screws and remove the cover.
3. Disconnect the conduit and wiring.
4. Close the isolation valves on the suction and discharge sides of the pump.

You must drain the system if no valves are installed.

5. Open the drain valve.

Do not proceed until liquid stops coming out of the drain valve. If liquid continues to
flow from the drain valve, the isolation valves are not sealing properly and you must
repair them before you proceed.

6. Leave the drain valve open.

Do not close the drain valve until the reassembly is complete.

7. Drain the liquid from the piping and flush the pump if it is necessary.
8. Disconnect all auxiliary piping and tubing.
9. Loosen the volute capscrews but do not remove them.
10. Shift the pump position slightly in order to allow the pressurized water to escape.

Maintenance

Series e-90 Close-Coupled In-Line Centrifugal Pumps Installation, Operation, and Maintenance Manual

15