Parameter list of the Extended Menù
Parameter list of the Extended Menù
Parameter list of the Extended Menù
Parameter list of the Extended Menù
Rif.
Rif.
Rif.
Rif. Parameter
Parameter
Parameter
Parameter
Model
Model
Model
Model
Read
Read
Read
Read
(R)
(R)
(R)
(R)
Write
Write
Write
Write
(RW)
(RW)
(RW)
(RW)
Unit
Unit
Unit
Unit
Min
Min
Min
Min
Max
Max
Max
Max
Defaul
Defaul
Defaul
Defaul
tttt
Description
Description
Description
Description
00
Password
MMA 
MMW 
 
00066 
(0074
0) 
Password for changing parameters in the Extended Menu - for reading only no 
password is needed. If password was set wrong the message: “???password=0…” will 
be displayed and values were not changed. 
01
fnom. motor
MMA 
MMW 
RW
Hz
39.99 99.99
45
Rated frequency of motor. This value f(nom) is indicated on the motor rating plate.
02
Language
MMA 
MMW 
RW
Italian Language selection.
03
f (Umax)
MMA 
MMW 
RW
Hz
29.99 99.99
50
Frequency applied to the motor to obtain Umax (e.g.: set 50 to obtain 230V at 50 Hz)
04* Configuration
MMA 
MMW 
RW
N.
0
2
1
This parameter must be set to default value “1”
05
Input Buffer
MMA 
MMW 
R
N.
0
255
Varie
Read digital inputs
06
Ramp 1 Acceler.
MMA 
MMW 
RW
sec
0.7
5
1.5
Time required for the output frequency applied to the motor to pass from zero to 
maximum frequency. 
07
Ramp 2 Deceler.
MMA 
MMW 
RW
sec
0.7
5
1.5
Time required for the output frequency applied to the motor to pass from maximum 
frequency to zero. 
08
JOG Frequency
MMA 
MMW 
RW
Hz
0
Par.(1)
50
Sets the frequency applied to the motor in the manual mode. In the operating mode 
(para 28) it must =0 
09
Drive State
MMA 
MMW 
R
0
0
107
Varie
Coded number, used to display driver state information. Examples: 0=off, 1=motor 
accelerating, 2=constant speed, 3=deceleration, 4=stopping, 5=stopped, 100=over 
current FF. 101=over current FT, 102=under voltage, 103=over voltage, 104=over 
temperature, 105=Short circuit shut-down, 106=protected I2T, 107=motor 
disconnected. 
10
MMA 
MMW 
R
0
0
104
Varie
Coded number, used to display hydraulic system information and measurements. 
0=Disabled, 1=Stop, 2=Run, 100=No water, 101=Insufficient pressure, 102=Pressure 
sensor fault, 103=Water hammering. 
11
fmin /MotorStop
MMA
RW
Hz
0
Par.(1)
10
Minimum permitted motor frequency. The driver shuts down below this value. Active if 
different from 0. 
12
Drive ResetTime
MMA
RW
sec
0.1
100
10
Delay between one motor start and the next following a driver fault. Driver 10X states