beautypg.com

Configurable multiple-function gate, New prod uc t, Absolute maximum ratings – Diodes 74LVC1G58 User Manual

Page 4: Recommended operating conditions

background image

74LVC1G58

CONFIGURABLE MULTIPLE-FUNCTION GATE

74LVC1G58

Document number DS35126 Rev. 4 - 2

4 of 15

www.diodes.com

June 2012

© Diodes Incorporated

NEW PROD

UC

T

Absolute Maximum Ratings

(Note 4)

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

KV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to 6.5

V

V

I

Input Voltage Range

-0.5 to 6.5

V

V

O

Voltage applied to output in high impedance or I

OFF

state

-0.5 to 6.5

V

V

O

Voltage applied to output in high or low state

-0.3 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

< 0

-50 mA

I

OK

Output Clamp Current

-50

mA

I

O

Continuous output current

±50

mA

Continuous current through Vdd or GND

±100

mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

Notes:

4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device

operation should be within recommend values

.

Recommended Operating Conditions

(Note 5)

Symbol

Parameter

Min

Max

Unit

V

CC

Operating Voltage

Operating 1.65

5.5

V

Data retention only

1.5

V

V

I

Input Voltage

0

5.5

V

V

O

Output Voltage

0

V

CC

V

I

OH

High-level output current

V

CC

= 1.65V

-4

mA

V

CC

= 2.3V

-8

V

CC

= 3V

-16

-24

V

CC

= 4.5V

-32

I

OL

Low-level output current

V

CC

= 1.65V

4

mA

V

CC

= 2.3V

8

V

CC

= 3V

16

24

V

CC

= 4.5V

32

Δt/ΔV

Input transition rise or fall rate

V

CC

= 1.8V ± 0.15V, 2.5V ± 0.2V

20

ns/V

V

CC

= 3.3V ± 0.3V

10

V

CC

= 5V ± 0.5V

5

T

A

Operating free-air temperature

-40

+125

ºC

Notes: 5. Unused inputs should be held at V

CC

or Ground.