Recommended operating conditions – Diodes 74LVC1G11 User Manual
Page 3

74LVC1G11
Document number: DS35122 Rev. 4 - 2
3 of 12
August 2013
© Diodes Incorporated
NEW PROD
UC
T
74LVC1G11
Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Min
Max
Unit
V
CC
Operating Voltage
Operating 1.65
5.5
V
Data Retention Only
1.5
V
V
IH
High-Level Input Voltage
V
CC
= 1.65V to 1.95V
0.65 X V
CC
V
V
CC
= 2.3V to 2.7V
1.7
V
CC
= 3V to 3.6V
2
V
CC
= 4.5V to 5.5V
0.7 X V
CC
V
IL
Low-Level Input Voltage
V
CC
= 1.65V to 1.95V
0.35 X V
CC
V
V
CC
= 2.3V to 2.7V
0.7
V
CC
= 3V to 3.6V
0.8
V
CC
= 4.5V to 5.5V
0.3 X V
CC
V
I
Input Voltage
0 5.5
V
V
O
Output Voltage
0
V
CC
V
I
OH
High-Level Output Current
V
CC
= 1.65V
-4
mA
V
CC
= 2.3V
-8
V
CC
= 3V
-16
-24
V
CC
= 4.5V
-32
I
OL
Low-Level Output Current
V
CC
= 1.65V
4
mA
V
CC
= 2.3V
8
V
CC
= 3V
16
24
V
CC
= 4.5V
32
Δt/ΔV
Input Transition Rise or Fall
Rate
V
CC
= 1.8V ± 0.15V, 2.5V ± 0.2V
20
ns/V
V
CC
= 3.3V ± 0.3V
10
V
CC
= 5V ± 0.5V
5
T
A
Operating Free-Air
Temperature
-40 +125
°C
Note:
5. Unused inputs should be held at V
CC
or Ground.