Absolute maximum ratings, Recommended operating conditions – Diodes 74AUP1G08 User Manual
Page 3
74AUP1G08
Document number: DS35150 Rev. 2 - 2
3 of 14
July 2013
© Diodes Incorporated
74AUP1G08
Absolute Maximum Ratings
(Note 4) (@T
A
= +25°C, unless otherwise specified.)
Symbol
Parameter
Rating
Unit
ESD HBM
Human Body Model ESD Protection
2
kV
ESD CDM
Charged Device Model ESD Protection
1
kV
V
CC
Supply Voltage Range
-0.5 to +4.6
V
V
I
Input Voltage Range
-0.5 to +4.6
V
V
o
Voltage applied to output in high or low state
-0.5 to V
CC
+0.5
V
I
IK
Input Clamp Current V
I
< 0
50
mA
I
OK
Output Clamp Current (V
O
< 0 )
50
mA
I
O
Continuous Output Current (V
O
= 0 to V
CC
)
±20 mA
I
CC
Continuous Current Through V
CC
50
mA
I
GND
Continuous Current Through GND
-50
mA
T
J
Operating Junction Temperature
-40 to +150
°C
T
STG
Storage Temperature
-65 to +150
°C
Note:
4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should be
within recommend values.
Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Min
Max
Unit
V
CC
Operating Voltage
0.8 3.6 V
V
I
Input Voltage
0 3.6 V
V
O
Output Voltage
0
V
CC
V
I
OH
High-Level Output Current
V
CC
= 0.8V
-20
µA
V
CC
= 1.1V
-1.1
mA
V
CC
= 1.4V
-1.7
V
CC
= 1.65V
-1.9
V
CC
= 2.3V
-3.1
V
CC
= 3.0V
-4
I
OL
Low-Level Output Current
V
CC
= 0.8V
20
µA
V
CC
= 1.1V
1.1
mA
V
CC
= 1.4V
1.7
V
CC
= 1.65V
1.9
V
CC
= 2.3V
3.1
V
CC
= 3.0V
4
Δt/ΔV
Input Transition Rise or Fall Rate
V
CC
= 0.8V to 3.6V
200
ns/V
T
A
Operating Free-Air Temperature
-40 +125 °C
Note:
5. Unused inputs should be held at V
CC
or Ground.