AH1810
Document number: DS35743 Rev. 2 - 2
3 of 7
August 2013
© Diodes Incorporated
AH1810
NEW PROD
UC
T
Absolute Maximum Ratings
(Note 5) @T
A
= +25°C, unless otherwise specified.)
Symbol Characteristics
Values
Unit
V
DD
Supply Voltage (Note 6)
6
V
V
DD_REV
Reverse Supply Voltage
-0.3
V
I
OUTPUT
Output current (source and sink)
2
mA
B
Magnetic Flux Density
Unlimited
P
D
Package
Power
Dissipation
SC59
270
mW
Ts
Storage Temperature Range
+150
°C
T
J
Maximum Junction Temperature
150
°C
ESD HBM
Human Body Model ESD capability
8
kV
Notes:
5. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
6. The absolute maximum V
DD
of 6V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate the
device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol Characteristic
Conditions
Rating Unit
V
DD
Supply Voltage
Operating
2.3 to 3.6
V
T
A
Operating Temperature Range
Operating
-40 to +85
°C
Electrical Characteristics
(@T
A
= +25°C, V
DD
= 2.3V to 3.6V, unless otherwise specified.)
Symbol Characteristic
Conditions Min
Typ
Max
Unit
V
OL
Output Low Voltage (on)
I
OUT
= 1mA
—
0.1
0.2
V
V
OH
Output High Voltage (off)
I
OUT
= -1mA
V
DD
-0.2 V
DD
-0.1 —
V
Ioff
Output Leakage Current
Vout=3.6V, B < Brps
—
<0.1 1 µA
I
DD
(awake)
Supply Current
During ‘awake’ period
—
2.1
—
mA
I
DD
(sleep)
During ‘sleep’ period
—
2.5 —
µA
I
DD
(avg)
Average Supply Current
V
DD
= 3.0V
—
6 10 µA
I
DD
(avg) V
DD
= 3.6V
—
7.3 13 µA
Tawake
Awake Active Pulse Width
(Note 7)
—
50 100 µs
Tperiod
Awake Period
(Note 7)
—
50 100 ms
D.C. Duty
Cycle
—
0.1 — %
Note:
7. When power is initially turned on, the operating V
DD
(1.6V to 3.6V) must be applied to guaranteed the output sampling.
The output state is valid after the second operating cycle (typical 100ms).