Advanced information ah342, Functional block diagram, Absolute maximum ratings – Diodes AH342 User Manual
Page 2: Recommended operating conditions
AH342
Document number: DS30886 Rev. 4 - 2
2 of 7
December 2013
© Diodes Incorporated
ADVANCED INFORMATION
AH342
Functional Block Diagram
660
510
OUTPUT AMP
7.5V
SOURCE
SINK
I
O
Voltage
Regulator
Hall
Sensor
Amp
and
Trigger
Interface
Circuit
Output
Amp
#1
Output
Amp
#2
IO
1
IO
2
Absolute Maximum Ratings
(@T
A
= +25°C, unless otherwise specified.) (Note 3)
Symbol Parameter
Rating
Unit
V
CC
Supply Voltage
±28
V
V
out
Voltage Externally Applied to Output
-1.2 to +5
V
Ic Output
Current
±10
mA
B
Magnetic Flux Density
Unlimited
Gauss
T
ST
Storage Temperature Range
-40to +150
°C
Note: 3. Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and
magnetic characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached nor will the
device necessarily operate at absolute maximum rating.
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol Characteristic
Conditions
Min
Max
Unit
V
CC
Supply Voltage
Operating
4.5
28
V
T
A
Operating Ambient Temperature (Note 4)
Operating
-40
+125
°C
Note: 4. Shall not exceed P
D
and Safety Operation Area.