Absolute maximum ratings, Recommended operating conditions, Ap7363 – Diodes AP7363 User Manual
Page 3

AP7363
Document number: DS35059 Rev. 8 - 2
3 of 14
December 2012
© Diodes Incorporated
AP7363
Absolute Maximum Ratings
(cont.) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Ratings
Unit
ESD HBM
Human Body Model ESD Protection
2000
V
ESD MM
Machine Model ESD Protection
200
V
V
IN
Input Voltage
-0.3 to +6.0
V
V
OUT
OUT Voltage
-0.3 to V
IN
+0.3
V
I
OUT
Continuous Load Current
Internal Limited
T
ST
Storage Temperature Range
-65 to +150
°C
T
J
Maximum Junction Temperature
150
°C
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Min
Max
Unit
V
IN
Input voltage
2.2
5.5
V
I
OUT
Output Current
0
1.5
A
T
A
Operating Ambient Temperature
-40
+85
°C
T
J
Operating Junction Temperature (Note 5)
-40
+125
°C
Notes:
4. Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated are not implied. Exposure to absolute-maximum rated
conditions for extended periods may affect device reliability.
5. Operating junction temperature must be evaluated and derated as needed, based on ambient temperature (T
A
), power dissipation (P
D
), maximum
allowable operating junction temperature (T
J-MAX
), and package thermal resistance (
θ
JA
).