Preliminary datasheet, Recommended operating conditions, Electrical characteristics – Diodes AP3410 User Manual
Page 5: Parameter symbol min max unit

Preliminary Datasheet
1.5MHz Synchronous Step-down DC-DC Converter AP3410
Mar. 2013 Rev. 1. 1 BCD Semiconductor Manufacturing Limited
5
Recommended Operating Conditions
Parameter Symbol
Min
Max
Unit
Supply Input Voltage
V
IN
2.5
5.5
V
Operating Ambient Temperature
T
A
-40
85
ºC
Operating Junction Temperature
T
J
-40
125
ºC
Electrical Characteristics
V
IN
=V
EN
=5V, V
OUT
=1.2V, V
FB
=0.6V, L=2.2
µH, C
IN
=4.7
µF, C
OUT
=10
µF, T
A
=25°C, unless otherwise
specified.
Parameters Symbol
Conditions Min
Typ
Max
Unit
Input Voltage Range
V
IN
2.5 5.5 V
Shutdown Current
I
OFF
V
EN
=0
0.1
µA
Active Current
I
ON
V
FB
=0.55V
220
µA
Regulated Feedback
Voltage
V
FB
0.588
0.6
0.612 V
Regulated Output
Voltage Accuracy
∆
V
OUT
/V
OUT
V
IN
=2.5V to 5.5V,
I
OUT
=0 to 1.2A
-3 3 %
Peak Inductor Current
I
PK
1.5
1.9
A
Oscillator Frequency
f
OSC
V
IN
=2.5V to 5.5V
1.2
1.5
1.8
MHz
PMOSFET R
DS(ON)
R
DS(ON)P
V
IN
=5V
200
m
Ω
NMOSFET R
DS(ON)
R
DS(ON)N
V
IN
=5V
200
m
Ω
EN High Level Input
Voltage
V
EN_H
1.5
V
EN Low Level Input
Voltage
V
EN_L
0.4
V
EN Input Current
I
EN
0.1
µA
Soft Start Time
t
SS
400
µs
Maximum Duty Cycle
D
MAX
100
%
Under Voltage Lock
Out Threshold
V
UVLO
Rising
2.3
V
Falling
2.1
Hysteresis
0.2
Thermal Shutdown
T
SD
Hysteresis=30°C
155
160
°C