SD12

Document number: DS31772 Rev. 6 - 2

2 of 5

www.diodes.com

February 2014

© Diodes Incorporated

SD12

ADVANCED INFORMATION




Maximum Ratings

(@T

A

= +25°C, unless otherwise specified.)

Characteristic Symbol

Value

Unit

Conditions

Peak Pulse Current

I

PP

15 A

8/20μs, Per Figure 3

ESD Protection – Contact Discharge

V

ESD_Contact

±30 kV

Standard IEC 61000-4-2

ESD Protection – Air Discharge

V

ESD_Air

±30 kV

Standard IEC 61000-4-2

ESD Protection – Human Body Model

V

ESD_HBM

±16 kV

Standard IEC 61000-4-2




Thermal Characteristics

Characteristic Symbol

Value

Unit

Package Power Dissipation (Note 5)

P

D

350 mW

Thermal Resistance, Junction to Ambient (Note 5)

R

θJA

500

°C/W

Operating Temperature Range

T

J

-55 to +150

°C

Storage Temperature Range

T

STG

-55 to +150

°C




Electrical Characteristics

(@T

A

= +25°C, unless otherwise specified.)

Characteristic Symbol

Min

Typ

Max

Unit

Test

Conditions

Reverse Working Voltage

V

RWM

12.0

V

Reverse Current (Note 6)

I

R

— — 1 μA

V

R

= V

RWM

= 12.0V

Reverse Breakdown Voltage (Note 6)

V

BR

13.3 — 15.75 V

I

R

= 1mA

Reverse Clamping Voltage

V

CL

— — 19

V

I

PP

= 5A, t

p

= 8/20μs

— 25

I

PP

= 15A, t

p

= 8/20μs

Capacitance

C

T

— — 150 pF

V

R

= 0V, f = 1MHz

Notes:

5. Device mounted on FR-4 PCB pad layout (2oz copper) as shown on Diodes, Inc. suggested pad layout AP02001, which can be found on our website at

http://www.diodes.com.

6. Short duration pulse test used to minimize self-heating effect.







0

120

160

200

400

200

300

40

80

100

0

T , AMBIENT TEMPERATURE ( C)

Figure 1 Power Derating Curve

A

°

P

,

P

O

WE

R

DI

SSI

P

A

T

IO

N (

m

W

)

D

Note 5

500

0

50

25

50

75

100 125

150

P

EAK

P

U

LS

E

D

E

R

A

T

IN

G

%

O

F

PE

AK P

O

W

E

R OR

CURRENT

T , AMBIENT TEMPERATURE (°C)

Figure 2 Pulse Derating Curve

A

0

100

25

75

175 200