4. IR ILLUmInATOR

Infrared illuminators are used in areas where the level of light is not sufficient for the unit to generate a

bright, clear image. An IR illuminator provides infrared light which, although invisible to the naked eye,

can greatly enhance the performance of night vision devices. Turn on the IR illuminator when working

in total darkness. Remember that the beam emitted by your IR illuminator will lose its brightness over

long distances.

IR ILLUmInATOR InSTALLATIOn

The IR810/IR850 is a removable infrared illuminator that can

be installed on the rail of the Nemesis. To install the IR illumi-

nator on your sight, perform the following:
1) Loosen the fixing screw on the IR illuminator mount.
2) Place the IR illuminator on the Picatinny rail
3) Tighten the fixing screw.

IR ILLUmInATOR OPERATIOn

The Armasight IR810/IR850 runs on a single CR123A battery. To install the battery, unscrew the battery

compartment cap and insert the battery in accordance with the polarity markings on the unit’s body.

Screw the battery compartment cap back into position.
To turn the IR illuminator on, rotate the operation switch from the OFF position.
To adjust the power and brightness of the beam emitted by the IR illuminator, rotate the illuminator

operation switch.
Focus the IR beam to change the field of coverage. To focus the beam, rotate the IR illuminator lens until

the image becomes clear.
Adjust the IR spot position in the field of view of the NVD as

follows:
1) Loosen the screw of the clamp on the IR illuminator

mount.
2) Turn on the sight and the IR illuminator.
3) Carefully move the lens of the IR illuminator up and down

and side to side. While looking through the eyepieces of

your device, observe the IR spot position.
4) Tighten the fixing screw of the clamp once the IR spot is

centered in the field of view.

6. mAInTEnAnCE PROCEDURES

The Nemesis should always be stored in the supplied packaging, particularly in heated and ventilated

rooms. To keep the device operational, please follow the instructions (below) regarding preparations

for storage. The battery should be stored separately from the device, and be inserted into the battery

compartment only when the device is being prepared for use. The presence of both acids and alkalis

near the device is not recommended.
While stored, your Nemesis should be protected from exposure to direct sunlight or extreme tempera-

tures.

nEmESIS CLEAnIng PROCEDURES

1) Gently remove any dirt from the sight’s body using a clean, soft cloth.
2) Wipe external surfaces down (with the exception of optical surfaces) with a clean cloth that has

been moistened with pure water.
3) Dry all wet surfaces with a different clean, dry cloth.
4) Carefully remove any dirt from the optical surfaces using a lens brush.

fOcus adjustment

fixing screW

battery cOmpartment

OperatiOn sWitch

screW Of clamp

beam directiOn