A. troubleshooting – Asus P/I-AP55TV User Manual
Page 88
82
ASUS P/I-AP55TV User's Manual
A. Troubleshooting
Test Patterns OK; Applications Do Not Sync
The wrong monitor type has been selected. Change the settings in the INSTALL
program.
Windows Driver Not Installing Properly
Windows must be running in 386 Enhanced Mode. Incompatible memory managers
may prevent Windows from starting in enhanced mode. If this occurs, remove the
offending driver or memory manager.
Windows NT 4.0 driver cannot pass "Test VGA."
Please bypass "Test VGA" then load ATI drivers after completing installation.
AutoCAD Driver Not Installing Properly
If using a 386, ensure that AutoCAD has been configured for the appropriate ADI
driver. The protected mode driver requires extended memory.
Error Codes and Messages
Problems and solutions for some common errors found by the test program are pro-
vided for your reference as follows:
Memory aperture test failure or Diagnostics program locks or Reboots during
aperture test
If you receive an error message indicating that the memory aperture location is con-
flicting with your system memory, restart the INSTALL program as follows: IN-
STALL APMAP
lect a location above but not overlapping System Memory (S), BIOS (B) or Re-
served (R) locations. Not applicable for ISA cards.
Desired resolution is disabled and displayed in gray
A mode displayed in gray means that the BIOS is told this mode is not available,
based on the card configuration. Re-install using custom monitor selection.
Menu item is disabled and displayed in gray
The test program has determined that the mode or test is not available under the
current configuration. Aperture tests are not available if the aperture is disabled, and
CRT mode and pixel depth are determined by current installation, DAC type, memory
size, and memory type.
(Error Codes)
A. T