2-25

6. CPU, chassis, power fan connectors

(3-pin CPU_FAN1, CHA_FAN1, PWR_FAN1)

The fan connectors support cooling fans of 350mA~740mA (8.88W
max.) or a total of 1A~2.22A (26.64W max.) at +12V. Connect the fan
cables to the fan connectors on the motherboard, making sure that the
black wire of each cable matches the ground pin of the connector.

Do not forget to connect the fan cables to the fan connectors. Lack of sufficient
air flow within the system may damage the motherboard components. These
are not jumpers! DO NOT place jumper caps on the fan connectors!

5. Chassis intrusion connector (4-1 pin CHASSIS1)

This lead is for a chassis designed with intrusion detection feature. This
requires an external detection mechanism such as a chassis intrusion sensor
or microswitch. When you remove any chassis component, the sensor
triggers and sends a high-level signal to this lead to record a chassis
intrusion event.

By default, the pins labeled “Chassis Signal” and “Ground” are shorted with a
jumper cap. If you wish to use the chassis intrusion detection feature, remove
the jumper cap from the pins.

P4P800S-E

®

P4P800S-E Chassis Alarm Lead

CHASSIS1

+5VSB_MB

Chassis Signal

GND

(Default)

P4P800S-E

®

P4P800S-E 12-Volt Fan Connectors

CPU_FAN1

CHA_FAN1

GND

Rotatio

n

+12V

GND

Rotation

+12V

PWR_FAN1

GND

Rotatio

n

+12V