7 remote access configuration, Remote access type [enabled, Serial port number [com1 – Asus M2N-LR/SATA User Manual
Page 82: Flow control [none, Redirection after bios post [always
ASUS M2N-LR Series
-2
Configure Remote Access type and parameters
Remote Access
[Enabled]
Serial port number
[COM1]
Base Address, IRQ
[3F8h, 4]
Serial Port Mode
[115200 8,n,1]
Flow Control
[None]
Redirection After BIOS POST
[Always]
Terminal Type
[ANSI]
VT-UTF8 Combo Key Support
[Enabled]
Media Type
[Serial]
Select Remote
Access type.
4.4.7
Remote Access Configuration
The items in this menu allows you to configure the Remote Access type and and
parameters.
Remote Access Type [Enabled]
Allows you to set the Remote Access Type.
Configuration options: [Disabled] [Enabled]
Serial port number [COM1]
Allows you to select the Serial Port for console redirection.
Configuration options: [COM1] [COM2]
Serial Port Mode [115200 8,n,1]
Allows you to select the Serial Port settings.
Configuration options: [115200 8,n,1] [57600 8,n,1] [38400 8,n,1] [19200 8,n,1]
[09600 8,n,1]
Flow Control [None]
Allows you to select the Flow Control for console redirection.
Configuration options: [None] [Hardware] [Software]
Redirection After BIOS POST [Always]
When set to [Boot Loader], console redirection is active during POST and during
Boot Loader. When set to [Always], redirection is always active. When set to
[Disabled], redirection is turned off after POST.
Configuration options: [Disabled] [Boot Loader] [Always]
When enabled, the following Remote Access types and parameters appear.