10/100/1000 Copper Port Aggregator Tap

8

Connecting_to_the_Monitoring_Device_

1 .. Supply.power.to.the.Tap.using.the.power.supplies.included.with.the.unit ..

Two.power.supplies.are.included ..The.use.of.the.second.redundant.power.

supply.is.optional ............................................................................

2 ..Verify.that.the.Power.LEDs.illuminate ..PWR.1.LED.illuminates.when.the.

first.power.supply.is.in.use,.and.PWR.2.LED.illuminates.when.the.second.

power.supply.is.in.use ..Both.power.supplies.can.be.plugged.into.the.Tap.at.

the.same.time .

3 .. Connect.Monitor.Port.1.and.Monitor.Port.2.to.the.appropriate.ports.on.the.

monitoring.devices.using.RJ45.CAT5e.straight-through.cables.to.monitor.

the.full-duplex.link .

Note:_________________________________________________________________

The second power supply is available to support the flow of traffic to the moni-

toring device, in the event that the first power supply becomes unavailable. If

the first power supply is unavailable, the second power supply will supply all

power for the Tap.

______________________________________________________________________

Figure_6._Connecting to the Monitoring Device

®

www.netoptics.com

1

2

Port Aggregator

1

Network

Monitor

2

A

B

10

100

1000

LINK
ACT

In-Line

To monitoring device 1

To monitoring device 2

Note:_________________________________________________________________

The monitor links connected to the 10/100/1000 Copper Port Aggregator must

run with autonegotiation. Be sure to configure the ports on the monitoring

tools for autonegotiation if you are cabling them to this device.

______________________________________________________________________ _